产品概述:PF0.9 online UPSGalleon II 1KVA-3KVA can provide high output power factor up to 0.9 and provide higher performance and efficiency for critical applications. It'···
PF0.9 online UPS
Galleon II 1KVA-3KVA can provide high output power factor up to 0.9, and provide higher performance and efficiency for critical applications. It's the same Galleon series with adjustable power management outlets that extend available battery time to critical devices by turning off unnecessary devices. This Galleon II 1KVA-3KVA series is also suitable for loads in laser printers and ultrasonic systems.
main feature
●1KVA/1.5KVA/2KVA/3KVA online UPS system
●Real double conversion online UPS system
● Wide input voltage range (110-300 VAC, 55-150 VAC)
●Input power correction factor 0.99
●Output power factor 0.9
●50/60Hz frequency conversion mode
●Adjustable power management socket
●Emergency power off function (EPO)
●ECO energy saving operation function
●High surge immunity, up to 7KVA, 13KVA, 1300J
●Optional matching generator
●High anti-overload capability and efficient short-circuit protection
●Multiple communication ports such as SNMP/USB/RS-232
●3-section intelligent charging design
●Maximum 8A extended parallel control can be used for long-running models
●Selectable output voltage: 200-240VAC, 100-127VAC
● Applicable to the load of laser printers and ultrasonic systems
Product Specifications
MODEL | Galleon II 1K (L) | Galleon II 1.5K (L) | Galleon II 2K (L) | Galleon II 3K (L) | |
capacity | 1000VA / 900W | 1500VA / 1350W | 2000VA / 1800W | 3000VA / 2700W | |
phase | Single phase with ground | ||||
ENTER | |||||
voltage range | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | ||||
Rated voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||||
Frequency Range | 40Hz~70Hz | ||||
power factor | ≧ 0.99 @ Nominal Voltage (100% load) | ||||
Harmonic Distortion (THDi) | ≦ 5% @100~130VAC or 205-245VAC; THDU < 1.6% @ input and full linear load condition with battery fully charged | ||||
OUTPUT | |||||
The output voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | ||||
AC Voltage Regulation (Voltage Mode) | ± 1% | ||||
Frequency Range (Battery Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
transfer time | AC mode is battery mode | Zero | |||
transfer time | Inverter to Bypass | 4 ms (Typical) | |||
Waveform (Battery Mode) | Pure Sine Wave | ||||
Current crest ratio | 3:1 | ||||
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) | ||||
Frequency range (sync range) | 47~53Hz or 57~63Hz | ||||
EFFICIENCY | |||||
battery mode | 89% | 90% | |||
ECO mode | 97% | ||||
Communication mode | 90% | 91% | |||
BATTERY | |||||
long extension machine | Module charging voltage | 41.0 VDC ± 1% | 82.1 VDC ± 1% | 82.1 VDC ± 1% ,109.6 VDC ± 1% | |
long extension machine | Module charging current (max) | 1A/2A/4A/6A/8A (Selectable) | |||
long extension machine | number of modules | 3 | 6 | 6,8 | |
long extension machine | Modular battery type | Depending on the capacity of external batteries | |||
Standard machine | Charger voltage | 41.0 VDC ± 1% | 82.1 VDC ± 1% | 82.1 VDC ± 1%, 109.6 VDC ± 1% | |
Standard machine | Charge current (max) | 1.5A | 1.5A, 1.2A | ||
Standard machine | Typical charging time | 4 hours recover to 90% capacity | |||
Standard machine | quantity | 3 | 6 | 6, 8 | |
Standard machine | Battery Type | 12V / 7Ah | 12V / 9Ah | 12V / 7Ah | 12V/9Ah, 12V/7Ah |
INDEX | |||||
LCD panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
ALARM | |||||
battery mode | Sounding every 5 seconds | ||||
low power | Sounding every 2 seconds | ||||
overload | Sounding every second | ||||
Fault | Continuously sounding | ||||
SURROUNDINGS | |||||
Working humidity | 20~95% RH @ 0- 40°C (non-condensing) | ||||
noise level | Less than 50dB @ 1 Meter | ||||
PHYSICS | |||||
Standard machine | Net weight/kg | 12 | 13.8 | 22.5 | 26.6, 32.2 |
Standard machine | Dimensions, D X W X H (mm) | 397 X 145 X 220 | 421 X 190 X 318 | ||
long extension machine | Net weight/kg | 6.3 | 6.5 | 10.5 | 11.7 |
long extension machine | Dimensions, D X W X H (mm) | 397 X 145 X 220 | 421 X 190 X 318 | ||
MANAGE | |||||
Optional SNMP | Power management from SNMP manager and web browser | ||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC |