Galleon One RT 1KVA-10KVA

Galleon One RT 1KVA-10KVA

产品概述:High-performance online UPS With a true double conversion design, the Galleon series provides powerful and comprehensive protection for your delicate equipment.···

产品简介

High-performance online UPS

With a true double-conversion design, the Galleon series provides powerful and comprehensive protection for your delicate equipment. It can accept a wider input voltage and is suitable for harsh power supply environments. It provides the perfect protection for your precious servers and high-performance workstations. Can be sold to the North American market.

main feature

●Real double conversion online UPS system

●Excellent microprocessor controller ensures high reliability

●Output power factor 1.0

●Input power correction

● Wide input voltage range (110-300 VAC)

●50/60Hz frequency conversion mode

●ECO energy saving operation function

●Emergency power off function (EPO)

●Built-in MOV overvoltage cut-off protection and surge immunity, which can realize full-time equipment protection

●Charger with capacity up to 1000W with extremely low ripple current when charging

●Low input current harmonics to reduce power system pollution

●The charging current can be directly adjusted through the LCD panel

●Intelligent battery charger design optimizes battery performance

●Compatible with engine input

       ●Optional external SNMP slot

       Product Specifications

MODELGalleon One RT 1KGalleon One RT 1.5KGalleon One RT 2KGalleon One RT 3KGalleon One 6K(L) RTGalleon One 10K(L) RT
phaseSingle phase with ground1 phase in / 1 phase out
capacity*1000 VA / 1000 W1500 VA / 1500 W2000 VA / 2000 W3000 VA / 3000 W6000 VA / 6000 W10000 VA / 10000 W
ENTER
voltage range55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load110-300 VAC ± 3 % at 50% load; 176~300 VAC ± 3 % at 100% load
Rated voltage100/110/115/120 /127 VAC or 200/208/220/230/240 VAC208/220/230/240 VAC
Frequency Range40Hz~70Hz46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz
Harmonic Distortion (THDi)≦ 5% @ nominal input voltage< 4% @100% Load, < 6% @50% Load
power factor≧ 0.99 @ Nominal Voltage (100% load)≧ 0.99 @ full load
OUTPUT
The output voltage100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC104/110/115/120VAC
AC Voltage Regulation (Voltage Mode)± 1%
Frequency Range (Battery Mode)50 Hz or 60 Hz ± 0.1 Hz50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
transfer timeAC mode is battery modeZero
transfer timeInverter to Bypass4 ms (Typical)zero
Waveform (Battery Mode)Pure Sine Wave
Current crest ratio3:1 (max.)
Harmonic Distortion≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)≦ 2% THD (Linear Load), ≦ 6% THD (Non-linear Load)
Frequency range (sync range)57~63 Hz or 47~53 Hz or46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz
overloadCommunication mode100%~110%: 10min、110%~130%: 1min、>130% : 1sec
overloadbattery mode100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec
EFFICIENCY
battery mode≧88%≧90%92%
ECO mode≧ 96% @ full charged battery98.5%
Communication mode≧ 89% @ full charged battery≧ 91% @ full charged battery94%
BATTERY
long extension machineCharging voltageN/A(13.65VDC x battery number) ± 1%
long extension machinequantityN/A16-20**
long extension machineMaximum charging currentN/A4.0 A
long extension machineBattery TypeN/ADepending on applications
Standard machineTypical charging time3 hours recover to 95% capacity for internal battery@ 2A charging current9 hours recover to 90% capacity
Standard machineCharging voltage27.4 VDC ± 1%, 41.1 VDC ± 1%41.1 VDC ± 1%54.8 VDC ± 1%, 82.1 VDC ± 1%82.1 VDC ± 1%218.4 VDC ± 1%218.4 VDC ± 1%
Standard machinerecharging current100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable, Default: 2A, Max: 8A adjustableDefault: 2A, Max: 8A adjustable1.0 A
Standard machinequantity2,334,6616
Standard machineBattery Type12 V / 9 AH, 12 V / 7 AH12 V / 9 AH12 V / 9 AH, 12 V / 7 AH12 V / 9 AH12 V / 7 AH12 V / 9 AH
INDEX
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
battery modeSounding every 5 secondsSounding every 4 seconds
low powerSounding every 2 secondsSounding every second
overloadSounding every secondSounding twice every seconds
FaultContinuously sounding
SURROUNDINGS
Working humidity20~90% RH @ 0- 40°C (non-condensing)
noise levelLess than 50dB @ 1 MeterLess than 55dB @ 1 MeterLess than 58dB @ 1 Meter
PHYSICS
Standard machineNet weight (built-in battery) (kg)11.6, 14.115.519.5, 23.3battery: 27.5UPS Unit: 17; Battery Pack: 48UPS Unit: 20; Battery Pack: 53
Standard machineDimensions, D X W X H (mm)410 x 438 x 88510 x 438 x 88, 630 x 438 x 88630 x 438 x 88UPS Unit: 610x 438 x 88 [2U]; Battery Pack: 715 x 438 x 88 [2U]UPS Unit: 610x 438 x 88 [2U]; Battery Pack: 715 x 438 x 88 [2U]
long extension machineNet weight (without battery) (kg)6.6, 7.88.19.4 , 10.612.41720
long extension machineDimensions, D X W X H (mm)410 x 438 x 88510 x 438 x 88, 630 x 438 x 88630 x 438 x 88610 x 438 x 88 [2U]
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
STANDARD
Safety verificationEMC EN62040-2 C2 for CE modelsN/A



Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)