产品概述:High-performance online UPS With a true double conversion design, the Galleon series provides powerful and comprehensive protection for your delicate equipment.···
High-performance online UPS
With a true double-conversion design, the Galleon series provides powerful and comprehensive protection for your delicate equipment. It can accept a wider input voltage and is suitable for harsh power supply environments. It provides the perfect protection for your precious servers and high-performance workstations. Can be sold to the North American market.
main feature
●Real double conversion online UPS system
●Excellent microprocessor controller ensures high reliability
●Output power factor 1.0
●Input power correction
● Wide input voltage range (110-300 VAC)
●50/60Hz frequency conversion mode
●ECO energy saving operation function
●Emergency power off function (EPO)
●Built-in MOV overvoltage cut-off protection and surge immunity, which can realize full-time equipment protection
●Charger with capacity up to 1000W with extremely low ripple current when charging
●Low input current harmonics to reduce power system pollution
●The charging current can be directly adjusted through the LCD panel
●Intelligent battery charger design optimizes battery performance
●Compatible with engine input
●Optional external SNMP slot
Product Specifications
MODEL | Galleon One RT 1K | Galleon One RT 1.5K | Galleon One RT 2K | Galleon One RT 3K | Galleon One 6K(L) RT | Galleon One 10K(L) RT | |
phase | Single phase with ground | 1 phase in / 1 phase out | |||||
capacity* | 1000 VA / 1000 W | 1500 VA / 1500 W | 2000 VA / 2000 W | 3000 VA / 3000 W | 6000 VA / 6000 W | 10000 VA / 10000 W | |
ENTER | |||||||
voltage range | 55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load | 110-300 VAC ± 3 % at 50% load; 176~300 VAC ± 3 % at 100% load | |||||
Rated voltage | 100/110/115/120 /127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | |||||
Frequency Range | 40Hz~70Hz | 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz | |||||
Harmonic Distortion (THDi) | ≦ 5% @ nominal input voltage | < 4% @100% Load, < 6% @50% Load | |||||
power factor | ≧ 0.99 @ Nominal Voltage (100% load) | ≧ 0.99 @ full load | |||||
OUTPUT | |||||||
The output voltage | 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC | 104/110/115/120VAC | |||||
AC Voltage Regulation (Voltage Mode) | ± 1% | ||||||
Frequency Range (Battery Mode) | 50 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||||
transfer time | AC mode is battery mode | Zero | |||||
transfer time | Inverter to Bypass | 4 ms (Typical) | zero | ||||
Waveform (Battery Mode) | Pure Sine Wave | ||||||
Current crest ratio | 3:1 (max.) | ||||||
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load) | ≦ 2% THD (Linear Load), ≦ 6% THD (Non-linear Load) | |||||
Frequency range (sync range) | 57~63 Hz or 47~53 Hz or | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz | |||||
overload | Communication mode | 100%~110%: 10min、110%~130%: 1min、>130% : 1sec | |||||
overload | battery mode | 100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec | |||||
EFFICIENCY | |||||||
battery mode | ≧88% | ≧90% | 92% | ||||
ECO mode | ≧ 96% @ full charged battery | 98.5% | |||||
Communication mode | ≧ 89% @ full charged battery | ≧ 91% @ full charged battery | 94% | ||||
BATTERY | |||||||
long extension machine | Charging voltage | N/A | (13.65VDC x battery number) ± 1% | ||||
long extension machine | quantity | N/A | 16-20** | ||||
long extension machine | Maximum charging current | N/A | 4.0 A | ||||
long extension machine | Battery Type | N/A | Depending on applications | ||||
Standard machine | Typical charging time | 3 hours recover to 95% capacity for internal battery@ 2A charging current | 9 hours recover to 90% capacity | ||||
Standard machine | Charging voltage | 27.4 VDC ± 1%, 41.1 VDC ± 1% | 41.1 VDC ± 1% | 54.8 VDC ± 1%, 82.1 VDC ± 1% | 82.1 VDC ± 1% | 218.4 VDC ± 1% | 218.4 VDC ± 1% |
Standard machine | recharging current | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable; 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable, Default: 2A, Max: 8A adjustable | Default: 2A, Max: 8A adjustable | 1.0 A | ||
Standard machine | quantity | 2,3 | 3 | 4,6 | 6 | 16 | |
Standard machine | Battery Type | 12 V / 9 AH, 12 V / 7 AH | 12 V / 9 AH | 12 V / 9 AH, 12 V / 7 AH | 12 V / 9 AH | 12 V / 7 AH | 12 V / 9 AH |
INDEX | |||||||
LCD panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||||
ALARM | |||||||
battery mode | Sounding every 5 seconds | Sounding every 4 seconds | |||||
low power | Sounding every 2 seconds | Sounding every second | |||||
overload | Sounding every second | Sounding twice every seconds | |||||
Fault | Continuously sounding | ||||||
SURROUNDINGS | |||||||
Working humidity | 20~90% RH @ 0- 40°C (non-condensing) | ||||||
noise level | Less than 50dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | ||||
PHYSICS | |||||||
Standard machine | Net weight (built-in battery) (kg) | 11.6, 14.1 | 15.5 | 19.5, 23.3 | battery: 27.5 | UPS Unit: 17; Battery Pack: 48 | UPS Unit: 20; Battery Pack: 53 |
Standard machine | Dimensions, D X W X H (mm) | 410 x 438 x 88 | 510 x 438 x 88, 630 x 438 x 88 | 630 x 438 x 88 | UPS Unit: 610x 438 x 88 [2U]; Battery Pack: 715 x 438 x 88 [2U] | UPS Unit: 610x 438 x 88 [2U]; Battery Pack: 715 x 438 x 88 [2U] | |
long extension machine | Net weight (without battery) (kg) | 6.6, 7.8 | 8.1 | 9.4 , 10.6 | 12.4 | 17 | 20 |
long extension machine | Dimensions, D X W X H (mm) | 410 x 438 x 88 | 510 x 438 x 88, 630 x 438 x 88 | 630 x 438 x 88 | 610 x 438 x 88 [2U] | ||
MANAGE | |||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC | ||||||
STANDARD | |||||||
Safety verification | EMC EN62040-2 C2 for CE models | N/A |