Galleon X9 II 1K-3KVA Rack/Tower

Galleon X9 II 1K-3KVA Rack/Tower

产品概述:The LCD display panel is easy to operate and adjust the viewing angle direction. Ideal for medium power density power protection needs, the Galleon X9 series is···

产品简介

The LCD display panel is easy to operate and adjust the viewing angle direction

Ideal for medium power density power protection needs, the Galleon X9 series is available in rack/tower form factors to suit a variety of environments. It has a small footprint, but the UPS has a built-in battery pack and can be accessed through the front panel for maintenance inspection and replacement, eliminating the need to remove the UPS from the rack mount. The LCD viewing angle can be easily adjusted by pressing a button on the LCD to correspond to rack or tower installations. In addition, IT staff can get the remaining battery backup time through the LCD display, so as to manage the equipment well.

main feature

●Real double conversion online UPS system

●Output power factor 0.9

●LCD display panel is easy to operate and adjust the viewing angle direction

●Rack and tower design

●Adjustable power management socket

●50/60Hz frequency conversion mode

●ECO energy saving operation function

●Emergency power off function (EPO)

●Hot-pull design, only for 1-3K models

●DSP technology is suitable for 6K and above models

●Active power factor correction is suitable for 6K and above models

●N+X parallel redundancy application is limited to 6K and above models

      product description

MODELGalleon X9 II 1KGalleon X9 II 1.5KGalleon X9 II 2KGalleon X9 II 3K
capacity1000 VA / 900 W1500 VA / 1350 W2000 VA / 1800 W3000 VA / 2700 W
phaseSingle phase with ground
ENTER
voltage range55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load; 80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load
Rated voltage100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
Frequency Range40Hz~70Hz
power factor≧ 0.99 @ Nominal Voltage (100% load)
Harmonic Distortion (THDi)≦ 5% @ nominal input voltage
OUTPUT
The output voltage100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC
AC Voltage Regulation (Voltage Mode)± 1%
Frequency Range (Battery Mode)50 Hz or 60 Hz ± 0.1 Hz
transfer timeZero
Waveform (Battery Mode)Pure Sine Wave
Current crest ratio3:1 (max.)
Harmonic Distortion≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear load)
Frequency range (sync range)57~63 Hz or 47~53 Hz or
EFFICIENCY
battery mode88%, 89%89%88%, 89%90%
ECO mode97%
Communication mode90%91%
BATTERY
long extension machineCharger voltage27.4 VDC ± 1%, 41.1 VDC ± 1%41.1 VDC ± 1%54.8 VDC ± 1%, 82.1 VDC ± 1%82.1 VDC ± 1%
long extension machineCharge current (max)1A / 2A / 4A / 8A
long extension machinenumber2,334, 66
long extension machineBattery TypeDepending on the capacity of external batteries
Standard machineCharger voltage27.4 VDC ± 1%, 41.1 VDC ± 1%41.1 VDC ± 1%54.8 VDC ± 1%, 82.1 VDC ± 1%82.1 VDC ± 1%
Standard machineCharge current (max)1.5 A
Standard machineTypical charging time4 hours recover to 90% capacity
Standard machinenumbertwenty three34, 66
Standard machineBattery Type12 V / 9 AH, 12 V / 7 AH12 V / 9 AH12 V / 9 AH, 12 V / 7 AH12 V / 9 AH
INDEX
LCD MonitorLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
battery modeSounding every 5 seconds
low powerSounding every 2 seconds
overloadSounding every second
FaultContinuously sounding
SURROUNDINGS
Working humidity20~90% RH @ 0- 40°C (non-condensing)
noise levelLess than 50dB @ 1 Meter
PHYSICS
Standard machineNet weight/kg11.6, 14.214.519.5, 26.927.4, 10.5
Standard machineDimensions, D X W X H (mm)410 x 438 x 88 [2U]510 x 438 x 88 [2U], 630 x 438 x 88 [2U]630 x 438 x 88 [2U]
long extension machineNet weight/kg6.46.510.5
long extension machineDimensions, D X W X H (mm)410 x 438 x 88510 x 438 x 88
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC


Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)