产品概述:The best priced online UPSWinner Pro+ is a high power density version of the Winner Pro series online UPS with an output power factor of 0.9. The whole machine ···
Best Priced Online UPS
Winner Pro+ is a high power density version of the Winner Pro series online UPS with an output power factor of 0.9. The whole machine is designed with a microprocessor controller in a small cabinet. Winner Pro+ also comes standard with USB and RS-232 communication ports, and a built-in smart slot that can be used with other signal protocol communication cards.
main feature
●Positive double conversion online UPS system
●Excellent microprocessor controller ensures high reliability
●Active power factor correction
●Output power factor 0.9
●Ultra wide input voltage range
●50/60Hz frequency conversion mode
●ECO energy-saving operation function, limited to 1-3KVA models
●The number of battery cells can be adjusted
●Compatible with engine input
●Remote management smart card function with USB or RS-232 interface
●Simple operation control through the display, and comprehensive display to monitor the UPS status
Product Specifications
MODEL | Winner Pro+ 1K | Winner Pro+ 2K | Winner Pro+ 3K | Winner Pro+ 6K | Winner Pro+ 10K | |
capacity | 1000 VA / 900 W | 2000 VA / 1800 W | 3000 VA / 2700 W | 6000 VA / 5400 W | 10000 VA / 9000 W | |
phase | Single phase with ground | |||||
ENTER | ||||||
voltage range | 60-145 VAC or 120-300 VAC (Based on load at 50%); 90-145 VAC or 180-280 VAC (Based on load at 100%) | 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%) | ||||
Rated voltage | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | ||||
Frequency Range | 40Hz ~70Hz | 46~54 Hz or 56~64 Hz | ||||
power factor | ≧ 0.99 @ Nominal Voltage (100% load) | |||||
OUTPUT | ||||||
Voltage regulation | ± 1% | |||||
The output voltage | 110/115/120/127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | ||||
Frequency Range (Battery Mode) | 50 Hz or 60 Hz ± 0.5% | 50 Hz or 60 Hz ± 0.1Hz | ||||
transfer time | AC mode is battery mode | Zero | ||||
transfer time | Inverter to Bypass | 4 ms (Typical) | Zero | |||
Waveform (Battery Mode) | Pure Sine Wave | |||||
Current crest ratio | 3:1 | |||||
Harmonic Distortion | ≦ 3% THD (Linear Load); ≦ 6% THD (Non-linear Load) | ≦ 3% THD (Linear Load); ≦ 5% THD (Non-linear Load) | ||||
Frequency range (sync range) | 47~53 Hz or 57~63 Hz | 46~54 Hz or 56~64 Hz | ||||
EFFICIENCY | ||||||
battery mode | 83% | 87% | 88% | 90% | 91% | |
AC mode | 88% | 89% | 90% | 92% | 93% | |
BATTERY | ||||||
long extension machine | Charger voltage | 41.0 VDC ± 1% | 82.1 VDC ± 1% | 273 VDC ± 1% (Based on 20pcs batteries) | ||
long extension machine | Charge current (max) | 1A/ 2A/ 4A/ 6A | 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) | |||
long extension machine | quantity | 3 | 6 | 16~20 (Adjustable) | ||
long extension machine | Battery Type | Dependeing on applications | ||||
Standard machine | Charger voltage | 27.4 VDC ± 1% or 41.0 VDC ± 1% | 54.7 VDC ± 1% or 82.1 VDC ± 1% | 82.1 VDC ± 1% | 218.4 VDC ± 1% or 273 VDC ± 1% | |
Standard machine | Charge current (max) | 1A | 1A/2A | |||
Standard machine | Typical charging time | 4 hours recover to 90% capacity | 9 hours recover to 90% capacity | |||
Standard machine | quantity | 2 or 3 | 4 or 6 | 6 | 16, 20 | |
Standard machine | Battery Type | 12 V / 9 AH | ||||
INDEX | ||||||
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | |||||
ALARM | ||||||
battery mode | Sounding every 4 seconds | |||||
low power | Sounding every second | |||||
overload | Sounding twice every second | |||||
Fault | Continuously sounding | |||||
SURROUNDINGS | ||||||
Working humidity | 20~90% RH @ 0- 40°C (non-condensing) | 0~95% RH @ 0- 50°C (non-condensing) | 0~95% RH @ 0-40°C (non-condensing) | |||
noise level | Less than 50dB @ 1 Meter | Less than 55dB @ 1 Meter | Less than 58dB @ 1 Meter | |||
PHYSICS | ||||||
Standard machine | Net weight/kg | 282 x 145 x 220 or 397 x 145 x 220 | 397 x 145 x 220 or 421 x 190 x 318 | 421 x 190 x 318 | 369 x 190 x 688 or 442 x 190 x 688 | 442 x 190 x 688 |
Standard machine | Dimensions, D X W X H (mm) | 9.8 or 11.4 | 17 or 26.2 | 27.6 | 61 or 74 | 66 or76 |
long extension machine | Net weight/kg | 282 x 145 x 220 | 397 x 145 x 220 | 369 x 190 x 318 | 442 x 190 x 318 | |
long extension machine | Dimensions, D X W X H (mm) | 4.4 | 6.8 | 7.6 | 12 | 16 |
MANAGE | ||||||
Optional SNMP | Power management from SNMP manager and web browser | |||||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC |