Otima II Tower 800VA-5KVA

Otima II Tower 800VA-5KVA

产品概述:The online interactive UPS Otima II Tower has a rated voltage range of 800VA to 5KVA and provides server-grade full power protection against power failures, spi···

产品简介

Online Interactive Uninterruptible Power System

Rated from 800VA to 5KVA, the Otima II Tower provides server-grade full power protection against power failures, spikes and surges in a small footprint with an output power factor of 0.9. This series is suitable for networking, telecom, server and mission critical applications.

main feature

●Pure sine wave

●Output power factor 0.9

●Adjustable power management socket

ECO (Efficiency Correction Optimizer) energy saving operation

●High-efficiency battery operation mode

Boost and Buck AVR for voltage stabilization

●Can provide a variety of communication ports

●3-section intelligent charging design

●Optional HID power supply USB port

      Product Specifications

MODELOtima II T 800Otima II T 1.1KOtima II T 1.5KOtima II T 2KOtima II T 2.5KOtima II T 3K
capacity800VA / 720W1100VA / 990W1500VA / 1350W2000VA / 1800W2500VA / 2250W3000VA / 2700W
ENTER
Rated voltage110/115/120/127VAC or 208/220/230/240VAC
acceptable voltage range81-152VAC or 162-290VAC
Frequency Range60/50 Hz (auto sensing)
OUTPUT
The output voltage110/115/120/127VAC or 208/220/230/240VAC
Frequency Range (Battery Mode)50 Hz or 60 Hz ± 1 Hz
transfer timeTypical 2-6 ms, 10ms max.
Waveform (Battery Mode)Pure Sine Wave
Voltage Regulation (Voltage Mode)± 1.5% (before battery alarm)
Current crest ratio3:1
Harmonic Distortion2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)
EFFICIENCY
battery mode≧ 88%, up to 90% @ nominal battery voltage≧89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC ≧91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC
Buck and Boost Modes95%
ECO mode97%
BATTERY
Typical charging time4 hours recover to 90% capacity
Charger voltage27.4 VDC ± 1%54.8 VDC ± 1%82.1 VDC ± 1%
Charge current (max)1.5A
Battery type and quantity12V/7Ah x 212V/9Ah x 212V/7Ah x 412V/9Ah x 412V/7Ah x 612V/9Ah x 6
PROTECT
full protectionOverload, discharge, and overcharge protection
INDEX
LCD MonitorAC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
ALARM
battery modeSounding every 10 seconds
low powerSounding every 2 seconds
overloadSounding every second
FaultContinuously sounding
SURROUNDINGS
Working humidity0~90% RH @ 0- 40°C (non-condensing)
noise levelLess than 45dB
PHYSICS
Dimensions, D X W X H (mm)397x145x220455 x 145 x 220421 x 190 x 318
Net weight/kg11.712.117.219.726.629
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
ModelOtima II T 5K
capacity5000VA / 4500W
ENTER
Rated voltage208/220/230/240VAC
acceptable voltage range162-290VAC
Frequency Range60/50 Hz (auto sensing)
OUTPUT
The output voltage208/220/230/240VAC
Frequency Range (Battery Mode)50 Hz or 60 Hz ± 1 Hz
transfer timeTypical 2-6 ms, 10ms max.
Waveform (Battery Mode)Pure Sine Wave
Voltage Regulation (Voltage Mode)± 1.5% (before battery alarm)
Current crest ratio3:1
Harmonic Distortion2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)
EFFICIENCY
battery mode≧91%, up to 92% @ nominal battery voltage
Buck and Boost Modes95%
ECO mode97%
BATTERY
Typical charging time4 hours recover to 90% capacity
Charger voltage82.1 VDC ± 1%
Charge current (max)1.5A
Battery type and quantity12V/10Ah x 6
PROTECT
full protectionOverload, discharge, and overcharge protection
INDEX
LCD MonitorAC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
ALARM
battery modeSounding every 10 seconds
low powerSounding every 2 seconds
overloadSounding every second
FaultContinuously sounding
SURROUNDINGS
Working humidity0~90% RH @ 0- 40°C (non-condensing)
noise levelLess than 45dB
PHYSICS
Dimensions, D X W X H (mm)421 x 190 x 318
Net weight/kg34.5
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC


Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)