产品概述:①Ripple and noise measurement method: Use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measur···
technical parameter:
project | Technical indicators | |||||
output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Rated current | 2A | 1.25A | 0.62A | 0.42A | 0.31A | |
rated power | 10W | 15.6W | 16.8W | 15.12W | 14.88W | |
Ripple and Noise① | <50mV | <120mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±2% | ±1% | ||||
Output voltage regulation range | ±10% | |||||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||||
Efficiency (Typical) ② | >78% | >82% | >84% | >84% | >84% | |
Working current | <0.3A 110VAC <0.15A 220VAC | |||||
electric shock | 110VAC 18A, 220VAC 36A | |||||
Start, rise, hold time | 200ms, 50ms, 20ms: 220VAC | |||||
Protect | Overload protection | ≥105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | ||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | |||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | ||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | |||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5KVAC Output-Case: 0.5KVAC for 1 minute | ||||
leakage current | Input-output <5mA at 1.5KVAC | |||||
leakage current | Input-output <1mA at 220VAC | |||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | |||||
other | size | 87*60*37mm | ||||
Net weight/gross weight | 150/175g | |||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②Efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25°C Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | |||||
output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Rated current | 4A | 2.1A | 1A | 0.7A | 0.52A | |
rated power | 20W | 25.2W | 24W | 25.2W | 24.96W | |
Ripple and Noise① | <50mV | <120mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±2% | ±1% | ||||
Output voltage regulation range | ±10% | |||||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||||
Efficiency (Typical) ② | >78% | >82% | >84% | >84% | >84% | |
Working current | <0.5A 110VAC <0.25A 220VAC | |||||
electric shock | 110VAC 18A, 220VAC 36A | |||||
Start, rise, hold time | 200ms, 50ms, 20ms: 220VAC | |||||
Protect | Overload protection | ≥105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | ||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | |||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | ||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | |||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5KVAC Output-Case: 0.5KVAC for 1 minute | ||||
leakage current | Input-output <5mA at 1.5KVAC | |||||
leakage current | Input-output <1mA at 220VAC | |||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | |||||
other | size | 87*60*37mm | ||||
Net weight/gross weight | 150/175g | |||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②Efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25°C Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | |||||
output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Rated current | 6A | 2.9A | 1.5A | 1A | 0.73A | |
rated power | 30W | 34.8W | 36W | 36W | 35W | |
Ripple and Noise① | <50mV | <120mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±2% | ±1% | ||||
Output voltage regulation range | ±10% | |||||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±0.5% | |||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||||
Efficiency ( Typical ) ② | >78% | >82% | >84% | >84% | > 84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||||
electric shock | 110VAC 18A , 220VAC 36A | |||||
Start, rise, hold time | 200ms , 50ms , 20ms : 220VAC | |||||
Protect | Overload protection | ≥105%-150% Type: constant current output + VO drops to undervoltage point, cut off output reset: re-power on | ||||
Short circuit protection | +VO drops to the undervoltage point, turns off the output | |||||
surroundings | Working temperature and humidity | -10 ℃~+50 ℃; 20% ~90RH | ||||
Storage temperature and humidity | -20 ℃~+85 ℃; 10% ~95RH | |||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5KVAC Output-Case: 0.5KVAC for 1 minute | ||||
leakage current | Input-output <5mA at 1.5KVAC | |||||
leakage current | Input-output <1mA at 220VAC | |||||
Isolation resistance | Input - Output, Input - Case, Output - Case : 500VDC/100M Ω | |||||
other | size | 87*60*37mm | ||||
Net weight/gross weight | 150/175g | |||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Test method for linear regulation rate: from low voltage to high voltage under rated load. Test method for load regulation rate: from 0% to 100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | |||||
output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Rated current | 8A | 4.2A | 2.1A | 1.4A | 1.1A | |
rated power | 40W | 50.4W | 50.4W | 50.4W | 52.8W | |
Ripple and Noise① | <50mV | <120mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±2% | ±1% | ||||
Output voltage regulation range | ± 10% | |||||
Load Regulation | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <± 0.5% | |
Linear adjustment rate | <±0.5% | |||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||||
Efficiency ( Typical ) ② | >78% | >82% | >84% | >84% | > 84% | |
Working current | <0.8A 110VAC <0.35A 220VAC | |||||
electric shock | 110VAC 18A , 220VAC 36A | |||||
Start, rise, hold time | 200ms , 50ms , 20ms : 220VAC | |||||
Protect | Overload protection | ≥105%-150% Type: constant current output + VO drops to undervoltage point, cut off output reset: re-power on | ||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | |||||
surroundings | Working temperature and humidity | -10 ℃~+50 ℃; 20% ~90RH | ||||
Storage temperature and humidity | -20 ℃~+85 ℃; 10% ~95RH | |||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5KVAC Output-Case: 0.5KVAC for 1 minute | ||||
leakage current | Input-output <5mA at 1.5KVAC | |||||
leakage current | Input-output <1mA at 220VAC | |||||
Isolation resistance | Input - Output, Input - Case, Output - Case : 500VDC/100M Ω | |||||
other | size | 111*78*36mm | ||||
Net weight/gross weight | 300/345g | |||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth . ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 29A | 14.5A | 9.7A | 7.3A | |
rated power | 350W | 350W | 350W | 350W | |
Ripple and Noise① | <120mV | <240mV | <240mV | <240mV | |
Voltage accuracy | ±1.0% | ||||
Output voltage regulation range | ±10% | ||||
Load Regulation | ±0.5% | ||||
Linear adjustment rate | ±0.5% | ||||
enter | voltage range | 90-132VAC/180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||
Efficiency (Typical) ② | >83% | >85% | >86% | >86% | |
Working current | 110VAC 25A, 220VAC: 50A | ||||
electric shock | <5.5A 115VAC <2.9A 230VAC | ||||
Start, rise, hold time | 200ms, 50ms, 20ms: 230VAC | ||||
Overload protection | 105%-135% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | ||||
Protect | Overvoltage protection | 115%-145% | |||
Under voltage protection | 10%-45%VOUT | ||||
temperature protection | RTH3: ≥55℃ fan start, ≤50℃ fan close, ≥85℃ close output (5V-15V) | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 2.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <6mA at 1.5KVAC | ||||
leakage current | Input-output <1.5mA at 220VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 199*98*38mm | |||
Net weight/gross weight | 616.3/654.3g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: from low voltage to high voltage under rated load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |