D series dual output 30~180 dual group switching power supply

D series dual output 30~180 dual group switching power supply

产品概述:The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude i···

产品简介

technical parameter:


projectD-30AD-30B
outputoutput channelCH1CH2CH1CH2
DC voltage                           5V12V5V24V
Rated current4A1A2A1A
Current range0.5-5A0.1-1.5A0.5-2A0.1-1A
rated power32W35W
Ripple and Noise①<50mV<120mV<50mV<120mV
Voltage accuracy±2%±10%±2%±10%
Output voltage regulation rangeCH1: ±10% 
Load Regulation ±1.5% ±3.0% ±1.5% ±3.0% 
Linear adjustment rate ±0.5% ±1.0% ±0.5% ±1.0% 
entervoltage range85-132VAC/176-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency (Typical) ②>78%>81%
Working current<0.75A 110VAC <0.4A 220VAC
electric shock110VAC 18A, 220VAC 45A
Start, rise, hold time500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC
ProtectOverload protection     105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on
Short circuit protection +VO drops to the undervoltage point to turn off the output 
surroundingsWorking temperature and humidity-10℃~+50℃; 20%~90RH    
Storage temperature and humidity-20℃~+85℃; 10%~95RH    
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <1mA at 220VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize129*98*38mm
Net weight/gross weight400/430g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth.

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear regulation and load regulation

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load 

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters.

projectD-50AD-50BD-50C
outputoutput channelCH1CH2CH1CH2CH1CH2
DC voltage                           5V12V5V24V12V24V
Rated current5A2A5A1A2A1A
Current range0.5-6A0.1-3A0.5-6A0.1-1.5A0.5-3A0.1-1.5A
rated power49W49W48W
Ripple and Noise①<50mV<120mV<50mV<120mV<120mV<120mV
Voltage accuracy±2%±10%±2%±10%±1.5%±10%
Output voltage regulation rangeCH1: ±10% 
Load Regulation ±1.5% ±3.0% ±1.5% ±3.0% ±1.5% ±3.0% 
Linear adjustment rate ±0.5% ±1.0% ±0.5% ±1.0% ±0.5% ±1.0% 
entervoltage range85-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency (Typical) ②>78%>81%>81%
Working current<1.1A 110VAC <0.65A 220VAC
electric shock110VAC 18A, 220VAC 45A
Start, rise, hold time500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC
ProtectOverload protection     105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on
Short circuit protection +VO drops to the undervoltage point to turn off the output 
surroundingsWorking temperature and humidity-10℃~+50℃; 20%~90RH    
Storage temperature and humidity-20℃~+85℃; 10%~95RH    
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <1mA at 220VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize159*98*38mm
Net weight/gross weight440/470g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. 

Accuracy: including setting error, linear adjustment rate and load adjustment rate. 

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load. 

The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000

projectD-60AD-60BD-60C
outputoutput channelCH1CH2CH1CH2CH1CH2
DC voltage                           5V12V5V24V12V24V
Rated current5A3A5A1.5A3A1A
Current range0.5-6A0.1-3.5A0.5-6A0.1-2A0.5-3.5A0.1-1.5A
rated power61W61W60W
Ripple and Noise①<50mV<120mV<50mV<120mV<120mV<120mV
Voltage accuracy±2%±10%±2%±10%±1.5%±10%
Output voltage regulation rangeCH1: ±10% 
Load Regulation ±1.5% ±3.0% ±1.5% ±3.0% ±1.5% ±3.0% 
Linear adjustment rate ±0.5% ±1.0% ±0.5% ±1.0% ±0.5% ±1.0% 
entervoltage range85-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency (Typical) ②>78%>81%>81%
Working current<1.1A 110VAC <0.65A 220VAC
electric shock110VAC 18A, 220VAC 45A
Start, rise, hold time500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC
ProtectOverload protection     105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on
Short circuit protection +VO drops to the undervoltage point to turn off the output 
surroundingsWorking temperature and humidity-10℃~+50℃; 20%~90RH    
Storage temperature and humidity-20℃~+85℃; 10%~95RH    
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <1mA at 220VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize159*98*38mm
Net weight/gross weight440/470g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. 

Accuracy: including setting error, linear adjustment rate and load adjustment rate. 

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters.

projectD-120AD-120BD-120C
outputoutput channelCH1CH2CH1CH2CH1CH2
DC voltage                           5V12V5V24V12V24V
Rated current12A5A12A2.5A5A2.5A
Current range0.5-15A0.1-7A0.5-15A0.1-3.5A0.5-7A0.1-3.5A
rated power120W120W120W
Ripple and Noise①<50mV<120mV<50mV<120mV<120mV<120mV
Voltage accuracy±2%±10%±2%±10%±1.5%±10%
Output voltage regulation rangeCH1: ±10% 
Load Regulation ±1.5% ±3.0% ±1.5% ±3.0% ±1.5% ±3.0% 
Linear adjustment rate ±0.5% ±1.0% ±0.5% ±1.0% ±0.5% ±1.0% 
entervoltage range85-132/180-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency (Typical) ②>78%>81%>81%
Working current<2.2A 110VAC <1.1A 220VAC
electric shock110VAC 20A, 220VAC 50A
Start, rise, hold time2000ms, 30ms, 20ms: 220VAC/1200ms, 30ms, 10ms: 115VAC
ProtectOverload protection     105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on
Short circuit protection +VO drops to the undervoltage point to turn off the output 
surroundingsWorking temperature and humidity-10℃~+50℃; 20%~90RH    
Storage temperature and humidity-20℃~+85℃; 10%~95RH    
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <2mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize199*110*50mm
Net weight/gross weight616.3/654.3g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time.

When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5℃/1000 meters

projectD-180AD-180BD-180C
outputoutput channelCH1CH2CH1CH2CH1CH2
DC voltage                           12V5V24V5V24V12V
Rated current12.5A6A6.25A6A5A5A
Current range1-15A0.5-7A1-7.5A0.5-7A1-7A0.5-6A
rated power180W180W180W
Ripple and Noise①<120mV<120mV<240mV<120mV<240mV<120mV
Voltage accuracy±2%±10%±2%±10%±1.5%±10%
Output voltage regulation rangeCH1  ± 10% 
Load Regulation ±1.5% ±3.0% ±1.5% ±3.0% ±1.5% ±3.0% 
Linear adjustment rate ±0.5% ±1.0% ±0.5% ±1.0% ±0.5% ±1.0% 
entervoltage range85-132/180-264VAC 47Hz~63Hz (254VDC~370VDC)
Efficiency Typical  ②>78%>81%>81%
Working current<2.5A 110VAC <1.2A 220VAC
electric shock110VAC 20A      220VAC 50A
Start, rise, hold time2000ms 30ms 20ms  220VAC/1200ms 30ms 10ms    115VAC
ProtectOverload protection     105%-150%   type: constant current output  +VO drops to under-voltage point,  cut off output  reset: re-power on
Short circuit protection +VO drops to the undervoltage point to  turn off the output 
surroundingsWorking temperature and humidity-10 ℃~+50 ℃; 20% 90RH    
Storage temperature and humidity-20 ℃~+85 ℃; 10% 95RH    
SafetyWithstand voltage Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute                                     
leakage currentInput-output <5mA at 1.5KVAC
leakage currentInput-output <2mA at 240VAC
Isolation resistanceInput Output,  Input Case,  Output Case  500VDC/100M Ω
othersize199*110*50mm
Net weight/gross weight616.3/654.3g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth.  

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear regulation and load regulation

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.


Excel Energy Co., Ltd.