产品概述:The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude i···
technical parameter:
project | D-30A | D-30B | |||
output | output channel | CH1 | CH2 | CH1 | CH2 |
DC voltage | 5V | 12V | 5V | 24V | |
Rated current | 4A | 1A | 2A | 1A | |
Current range | 0.5-5A | 0.1-1.5A | 0.5-2A | 0.1-1A | |
rated power | 32W | 35W | |||
Ripple and Noise① | <50mV | <120mV | <50mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | |
Output voltage regulation range | CH1: ±10% | ||||
Load Regulation | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
enter | voltage range | 85-132VAC/176-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >81% | |||
Working current | <0.75A 110VAC <0.4A 220VAC | ||||
electric shock | 110VAC 18A, 220VAC 45A | ||||
Start, rise, hold time | 500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC | ||||
Protect | Overload protection | 105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <5mA at 1.5KVAC | ||||
leakage current | Input-output <1mA at 220VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 129*98*38mm | |||
Net weight/gross weight | 400/430g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear regulation and load regulation Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | D-50A | D-50B | D-50C | ||||
output | output channel | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 5V | 12V | 5V | 24V | 12V | 24V | |
Rated current | 5A | 2A | 5A | 1A | 2A | 1A | |
Current range | 0.5-6A | 0.1-3A | 0.5-6A | 0.1-1.5A | 0.5-3A | 0.1-1.5A | |
rated power | 49W | 49W | 48W | ||||
Ripple and Noise① | <50mV | <120mV | <50mV | <120mV | <120mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | ±1.5% | ±10% | |
Output voltage regulation range | CH1: ±10% | ||||||
Load Regulation | ±1.5% | ±3.0% | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
enter | voltage range | 85-264VAC 47Hz~63Hz (254VDC~370VDC) | |||||
Efficiency (Typical) ② | >78% | >81% | >81% | ||||
Working current | <1.1A 110VAC <0.65A 220VAC | ||||||
electric shock | 110VAC 18A, 220VAC 45A | ||||||
Start, rise, hold time | 500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC | ||||||
Protect | Overload protection | 105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||||
leakage current | Input-output <5mA at 1.5KVAC | ||||||
leakage current | Input-output <1mA at 220VAC | ||||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||||
other | size | 159*98*38mm | |||||
Net weight/gross weight | 440/470g | ||||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 |
project | D-60A | D-60B | D-60C | ||||
output | output channel | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 5V | 12V | 5V | 24V | 12V | 24V | |
Rated current | 5A | 3A | 5A | 1.5A | 3A | 1A | |
Current range | 0.5-6A | 0.1-3.5A | 0.5-6A | 0.1-2A | 0.5-3.5A | 0.1-1.5A | |
rated power | 61W | 61W | 60W | ||||
Ripple and Noise① | <50mV | <120mV | <50mV | <120mV | <120mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | ±1.5% | ±10% | |
Output voltage regulation range | CH1: ±10% | ||||||
Load Regulation | ±1.5% | ±3.0% | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
enter | voltage range | 85-264VAC 47Hz~63Hz (254VDC~370VDC) | |||||
Efficiency (Typical) ② | >78% | >81% | >81% | ||||
Working current | <1.1A 110VAC <0.65A 220VAC | ||||||
electric shock | 110VAC 18A, 220VAC 45A | ||||||
Start, rise, hold time | 500ms, 30ms, 50ms: 220VAC/1200ms, 30ms, 10ms: 115VAC | ||||||
Protect | Overload protection | 105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||||
leakage current | Input-output <5mA at 1.5KVAC | ||||||
leakage current | Input-output <1mA at 220VAC | ||||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||||
other | size | 159*98*38mm | |||||
Net weight/gross weight | 440/470g | ||||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | D-120A | D-120B | D-120C | ||||
output | output channel | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 5V | 12V | 5V | 24V | 12V | 24V | |
Rated current | 12A | 5A | 12A | 2.5A | 5A | 2.5A | |
Current range | 0.5-15A | 0.1-7A | 0.5-15A | 0.1-3.5A | 0.5-7A | 0.1-3.5A | |
rated power | 120W | 120W | 120W | ||||
Ripple and Noise① | <50mV | <120mV | <50mV | <120mV | <120mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | ±1.5% | ±10% | |
Output voltage regulation range | CH1: ±10% | ||||||
Load Regulation | ±1.5% | ±3.0% | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
enter | voltage range | 85-132/180-264VAC 47Hz~63Hz (254VDC~370VDC) | |||||
Efficiency (Typical) ② | >78% | >81% | >81% | ||||
Working current | <2.2A 110VAC <1.1A 220VAC | ||||||
electric shock | 110VAC 20A, 220VAC 50A | ||||||
Start, rise, hold time | 2000ms, 30ms, 20ms: 220VAC/1200ms, 30ms, 10ms: 115VAC | ||||||
Protect | Overload protection | 105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||||
leakage current | Input-output <5mA at 1.5KVAC | ||||||
leakage current | Input-output <2mA at 240VAC | ||||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||||
other | size | 199*110*50mm | |||||
Net weight/gross weight | 616.3/654.3g | ||||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5℃/1000 meters |
project | D-180A | D-180B | D-180C | ||||
output | output channel | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
DC voltage | 12V | 5V | 24V | 5V | 24V | 12V | |
Rated current | 12.5A | 6A | 6.25A | 6A | 5A | 5A | |
Current range | 1-15A | 0.5-7A | 1-7.5A | 0.5-7A | 1-7A | 0.5-6A | |
rated power | 180W | 180W | 180W | ||||
Ripple and Noise① | <120mV | <120mV | <240mV | <120mV | <240mV | <120mV | |
Voltage accuracy | ±2% | ±10% | ±2% | ±10% | ±1.5% | ±10% | |
Output voltage regulation range | CH1 : ± 10% | ||||||
Load Regulation | ±1.5% | ±3.0% | ±1.5% | ±3.0% | ±1.5% | ±3.0% | |
Linear adjustment rate | ±0.5% | ±1.0% | ±0.5% | ±1.0% | ±0.5% | ±1.0% | |
enter | voltage range | 85-132/180-264VAC 47Hz~63Hz (254VDC~370VDC) | |||||
Efficiency ( Typical ) ② | >78% | >81% | >81% | ||||
Working current | <2.5A 110VAC <1.2A 220VAC | ||||||
electric shock | 110VAC 20A , 220VAC 50A | ||||||
Start, rise, hold time | 2000ms , 30ms , 20ms : 220VAC/1200ms , 30ms , 10ms : 115VAC | ||||||
Protect | Overload protection | 105%-150% type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||||
surroundings | Working temperature and humidity | -10 ℃~+50 ℃; 20% ~90RH | |||||
Storage temperature and humidity | -20 ℃~+85 ℃; 10% ~95RH | ||||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||||
leakage current | Input-output <5mA at 1.5KVAC | ||||||
leakage current | Input-output <2mA at 240VAC | ||||||
Isolation resistance | Input - Output, Input - Case, Output - Case : 500VDC/100M Ω | ||||||
other | size | 199*110*50mm | |||||
Net weight/gross weight | 616.3/654.3g | ||||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear regulation and load regulation Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. |