产品概述:Technical parameters: project Q-60BQ-60CQ-60D output output channel CH1CH2CH3CH4CH1CH2CH3CH4CH1CH2CH3CH4 DC voltage 5V12V-5V-12V5V15V-5V-15V5V12V24V-12V rated c···
technical parameter:
project | Q-60B | Q-60C | Q-60D | ||||||||||
output | output channel | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 |
DC voltage | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V | |
Rated current | 5A | 2A | 0.5A | 0.5A | 5A | 1.5A | 0.5A | 0.5A | 3A | 1A | 1A | 0.5A | |
Current range | 0.5-6A | 0.2-3A | 0-1A | 0-1A | 0.5-6A | 0.2-2A | 0-1A | 0-1A | 0.5-4A | 0.2-1.5A | 0.1-1A | 0-1A | |
rated power | 57.5W | 57.5W | 57W | ||||||||||
Ripple and Noise① | 80mV | 120mV | 100mV | 120mV | 80mV | 120mV | 100mV | 120mV | 80mV | 120mV | 150mV | 120mV | |
Voltage accuracy | ±2% | ±6% | ±3% | ±3% | ±2% | ±6% | ±3% | ±3% | ±2% | ±6% | +7, -5% | ±3% | |
Output voltage regulation range | CH1: ±10% | ||||||||||||
Load Regulation | ±0.5% | ±3.0% | ±1.0% | ±1.0% | ±0.5% | ±3.0% | ±1.0% | ±1.0% | ±0.5% | ±3.0% | ±3.0% | ±1.0% | |
Linear adjustment rate | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±0.5% | ±1.5% | ±2.0% | ±0.5% | |
enter | voltage range | 85-264VAC 47Hz~63Hz (254VDC~370VDC) | |||||||||||
Efficiency (Typical) ② | >78% | >78% | >80% | ||||||||||
Working current | <1.1A 110VAC <0.6A 220VAC | ||||||||||||
electric shock | 110VAC 18A, 220VAC 45A | ||||||||||||
Start, rise, hold time | 900ms, 20ms, 20ms: 220VAC/800ms, 20ms, 10ms: 115VAC | ||||||||||||
Protect | Overload protection | 105%-150% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||||||||||
Short circuit protection | +VO drops to the undervoltage point to turn off the output | ||||||||||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||||||||||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||||||||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||||||||||
leakage current | Input-output <5mA at 1.5KVAC | ||||||||||||
leakage current | Input-output <2mA at 240VAC | ||||||||||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||||||||||
other | size | 159*98*38mm | |||||||||||
Net weight/gross weight | 440/470g | ||||||||||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear regulation and load regulation Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |