产品概述:Technical reference: Project technical indicators Output DC voltage 5V12V15V24V Rated current 3A2A2A1.5A Rated power 15W24W30W36W Ripple and noise ①<80mV<120mV<···
Technical reference:
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 15V | 24V |
Rated current | 3A | 2A | 2A | 1.5A | |
rated power | 15W | 24W | 30W | 36W | |
Ripple and Noise① | <80mV | <120mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | |||
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1% | ||||
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >82% | >84% | >84% | |
Working current | <0.8A 110VAC <0.4A 220VAC | ||||
electric shock | 110VAC 15A, 220VAC 30A | ||||
Start, rise, hold time | 100ms, 30ms, 21ms: 110VAC/100ms, 30ms, 100ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Short circuit protection | +VO drops to the undervoltage point and turns off the output Automatic recovery after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 78*93*56mm | |||
Net weight/gross weight | 270/290g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 15V | 24V |
Rated current | 5A | 3.5A | 2.8A | 2A | |
rated power | 25W | 42W | 42W | 48W | |
Ripple and Noise① | <80mV | <120mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | |||
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1% | ||||
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >82% | >84% | >84% | |
Working current | <1A 110VAC <0.5A 220VAC | ||||
electric shock | 110VAC 15A, 220VAC 30A | ||||
Start, rise, hold time | 100ms, 30ms, 21ms: 110VAC/100ms, 30ms, 100ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Short circuit protection | +VO drops to the undervoltage point and turns off the output Automatic recovery after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 78*93*56mm | |||
Net weight/gross weight | 270/290g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 15V | 24V |
Rated current | 6.5A | 4.5A | 4A | 2.5A | |
rated power | 32.5W | 54W | 60W | 60W | |
Ripple and Noise① | <80mV | <120mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | |||
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1% | ||||
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >82% | >84% | >84% | |
Working current | <1.2A 110VAC <0.8A 220VAC | ||||
electric shock | 110VAC 15A, 220VAC 30A | ||||
Start, rise, hold time | 100ms, 30ms, 21ms: 110VAC/100ms, 30ms, 100ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Short circuit protection | +VO drops to the undervoltage point and turns off the output Automatic recovery after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 78*93*56mm | |||
Net weight/gross weight | 270/290g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | |||
output | DC voltage | 12V | 24V | 48V |
Rated current | 6.3A | 3.2A | 1.6A | |
rated power | 76W | 76.8W | 76.8W | |
Ripple and Noise① | <120mV | <150mV | <240mV | |
Voltage accuracy | ±2% | ±1% | ||
Output voltage regulation range | ±10% | |||
Load Regulation | ±1% | |||
Linear adjustment rate | ±0.5% | |||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (Typical) ② | >86% | >88% | >90% | |
Working current | <1.6A 110VAC <0.96A 220VAC | |||
electric shock | 110VAC 20A, 220VAC 40A | |||
Start, rise, hold time | 1800ms, 60ms, 12ms: 110VAC/1000ms, 60ms, 60ms: 220VAC | |||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | ||
Short circuit protection | +VO drops to the undervoltage point and turns off the output Automatic recovery after the abnormal condition is removed | |||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | ||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | |||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | ||
leakage current | <1mA/240VAC | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | |||
other | size | 55.5*125.2*100mm | ||
Net weight/gross weight | 600/650g | |||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||
output | DC voltage | 24V | 48V |
Rated current | 20A | 10A | |
rated power | 480W | 480W | |
Ripple and Noise① | <120mV | <240mV | |
Voltage accuracy | ±1% | ±1% | |
Output voltage regulation range | ±10% | ||
Load Regulation | ±1% | ||
Linear adjustment rate | ±0.5% | ||
enter | voltage range | 180-264VAC 47Hz~63Hz (270VDC~370VDC) | |
Efficiency (Typical) ② | >84% | >86% | |
Working current | <2.5A 110VAC <1.3A 220VAC | ||
electric shock | 110VAC 20A, 220VAC 35A | ||
Start, rise, hold time | 3000ms, 100ms, 22ms: 110VAC/1500ms, 100ms, 28ms: 220VAC | ||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |
Overvoltage protection | When the output voltage is greater than 135%, the output is turned off. Automatic recovery after the abnormal condition is removed | ||
Short circuit protection | +VO drops to the undervoltage point and turns off the output. After the abnormal condition is removed, it will resume automatically after the power is restarted. | ||
Over temperature protection | When >85°, the output will be turned off. After the temperature has dropped, it will be restored after the power is restarted. | ||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | |
leakage current | <1.5mA/240VAC | ||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||
other | size | 125.5*100*125.2mm | |
Net weight/gross weight | 1200/1230g | ||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |