LPV series 10~300 waterproof glue filling switching power supply

LPV series 10~300 waterproof glue filling switching power supply

产品概述:Technical parameters: The technical indicators of each specification of this series are grouped into main output group, charging group, control lock group, outp···

产品简介

technical parameter:

projectSpecifications of this series
groupingmain output groupcharging packlock group
outputDC output voltage18V20V12V
Rated output current0-3A0-0.5A0-2A
Rated output power60W
Ripple and Noise①<240mV
Load Regulation<±0.5%
Incoming line adjustment rate<±0.5%
enterCL portExternal 18VDC signal
Efficiency Typical  ②>82%
Input voltage range85-264VAC, 47Hz 63Hz (120VDC 370VDC)
Input inrush current110VAC/18A      220VAC/36A
Maximum input operating current<1.2A 110VAC <0.6A 220VAC
Start, rise, hold time200ms 50ms 20ms  230VAC
ProtectBattery undervoltage protectionWhen the battery voltage is less than 17.5V, the circuit is open to stop discharging.
Overload protection105%-150%   type: constant power  overload 110-130%   cut off output  reset: disconnect or reduce the load
Short circuit protectionIn the event of a short circuit at the output: the output is switched off.
Pressure resistanceWithstand voltageInput-Output: 1.5KVAC Input-Case: 1.5KVAC Output-Case: 0.5KVAC for 1 minute
leakage currentInput-output <3.5mA at 1.5KVAC
leakage currentInput-output <0.3mA at 220VAC
Isolation resistanceInput Output,  Input Case,  Output Case  500VDC/100M Ω
otherWorking temperature and humidity-10 ℃~+50 ℃; 20% 90RH    
Storage temperature and humidity-20 ℃~+85 ℃; 10% 95RH    
size159*98*38mm
Net weight/gross weight450/500g (lead-free battery)
Prepare enoughNote :    ①When  inputting 88VAC/176VAC ②When inputting  220VAC You need to prepare 18 V lead- acid battery by yourself (recommended configuration current is ≥5 AH)       
project
outputDC voltage5V12V15V24V
Rated current3A1.67A1.33A0.84A
rated power15W20W20W20.2W
Ripple and Noise①<80mV<120mV<120mV<150mV
Voltage accuracy±5%
Load Regulation±2%
Linear adjustment rate±1%
Start, rise, hold time500ms, 20ms, 16ms: 115VAC 500ms, 20ms, 50ms: 230VAC
entervoltage range90-264VAC 47Hz~63Hz; 127VDC~370VDC
Efficiency Typical  ②>77%>81%>83%>83%
Working current0.55A/110VAC 0.35A/230VAC
electric shock220VAC: 60A
ProtectOverload protectionWhen the output rated power is greater than or equal to 105%-135%: Protection mode: hiccup mode, it can automatically recover after the abnormal condition is removed.
Overvoltage protectionWhen the output voltage is greater than or equal to 115%-145%: protection mode: hiccup mode, it can automatically recover after removing the abnormal condition.
surroundingsWorking temperature and humidity-30℃~+70℃; 20%~90RH    
Storage temperature and humidity-40℃~+85℃; 10%~95RH    
SafetyWithstand voltageInput-Output: 3KVAC for 1 minute
leakage currentInput-case <2.5mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize117*29*20mm
Net weight/gross weight900/1200g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time.

project
outputDC voltage5V12V15V24V
Rated current4A2.5A2A1.25
rated power20W30W30W30W
Ripple and Noise①<80mV<120mV<120mV<150mV
Voltage accuracy±5%
Load Regulation±2%
Linear adjustment rate±1%
Start, rise, hold time500ms, 20ms, 16ms: 115VAC 500ms, 20ms, 50ms: 230VAC
entervoltage range90-264VAC 47Hz~63Hz; 127VDC~370VDC
Efficiency Typical  ②>77%>81%>83%>83%
Working current1A/110VAC 0.65A/230VAC
electric shock220VAC: 60A
ProtectOverload protectionWhen the output rated power is greater than or equal to 105%-135%: Protection mode: hiccup mode, it can automatically recover after the abnormal condition is removed.
Overvoltage protectionWhen the output voltage is greater than or equal to 115%-145%: protection mode: hiccup mode, it can automatically recover after removing the abnormal condition.
surroundingsWorking temperature and humidity-30℃~+70℃; 20%~90RH    
Storage temperature and humidity-40℃~+85℃; 10%~95RH    
SafetyWithstand voltageInput-Output: 3KVAC for 1 minute
leakage currentInput-case <2.5mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize220*29*20mm
Net weight/gross weight900/1200g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time.

project
outputDC voltage5V12V15V24V
Rated current10A5A4A2.5A
rated power50W60W60W60W
Ripple and Noise①<80mV<120mV<120mV<150mV
Voltage accuracy±5%
Load Regulation±2%
Linear adjustment rate±1%
Start, rise, hold time500ms, 20ms, 16ms: 115VAC 500ms, 20ms, 50ms: 230VAC
entervoltage range90-264VAC 47Hz~63Hz; 127VDC~370VDC
Efficiency Typical  ②>77%>81%>83%>83%
Working current1.5A/110VAC 1.1A/230VAC
electric shock220VAC: 60A
ProtectOverload protectionWhen the output rated power is greater than or equal to 105%-135%: Protection mode: hiccup mode, it can automatically recover after the abnormal condition is removed.
Overvoltage protectionWhen the output voltage is greater than or equal to 115%-145%: protection mode: hiccup mode, it can automatically recover after removing the abnormal condition.
surroundingsWorking temperature and humidity-30℃~+70℃; 20%~90RH    
Storage temperature and humidity-40℃~+85℃; 10%~95RH    
SafetyWithstand voltageInput-Output: 3KVAC for 1 minute
leakage currentInput-case <2.5mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize168*48*33mm
Net weight/gross weight900/1200g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time.

project
outputDC voltage12V15V24V36V
Rated current25A20A12.5A8.3A
rated power300W300W300W298.8W
Ripple and Noise①<120mV<120mV<200mV<240mV
Voltage accuracy±5%
Load Regulation±2%
Linear adjustment rate±1%
Start, rise, hold time2000ms, 25ms, 15ms: 115VAC 2000ms, 25ms, 50ms: 230VAC
entervoltage range90-264VAC 47Hz~63Hz; 127VDC~370VDC
Efficiency Typical  ②>87%>88%>88%>89%
Working current4.5A/110VAC 2.7A/230VAC
electric shock220VAC: 60A
ProtectOverload protectionWhen the output rated power is greater than or equal to 105%-135%: Protection mode: hiccup mode, it can automatically recover after the abnormal condition is removed.
Overvoltage protectionWhen the output voltage is greater than or equal to 115%-145%: protection mode: hiccup mode, it can automatically recover after removing the abnormal condition.
surroundingsWorking temperature and humidity-30℃~+70℃; 20%~90RH    
Storage temperature and humidity-40℃~+85℃; 10%~95RH    
SafetyWithstand voltageInput-Output: 3KVAC for 1 minute
leakage currentInput-case <2.5mA at 240VAC
Isolation resistanceInput-Output, Input-Case, Output-Case: 500VDC/100MΩ
othersize220.4*130*48mm
Net weight/gross weight900/1200g
Remark

①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth

②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load

Load regulation test method: from 0%-100% rated load.

The start-up time is measured in a cold start state. Rapid and frequent switching of the machine may increase the start-up time.


Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)