产品概述:Technical parameters: Project technical indicators Output DC voltage 5V12V15V24V Rated current 2A0.84A0.67A0.42A Rated power 10W10W10W10W Ripple and noise ①<80m···
technical parameter:
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 15V | 24V |
Rated current | 2A | 0.84A | 0.67A | 0.42A | |
rated power | 10W | 10W | 10W | 10W | |
Ripple and Noise① | <80mV | <120mV | <120mV | <150mV | |
Voltage accuracy | ±5% | ±3% | ±3% | ±2% | |
Output voltage regulation range | ±10% | ||||
Load Regulation | ±5% | ±3% | ±3% | ±2% | |
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >77% | >81% | >81% | >84% | |
Working current | <0.33A 110VAC <0.21A 220VAC | ||||
electric shock | 110VAC 35A, 220VAC 70A | ||||
Start, rise, hold time | 1000ms, 30ms, 25ms: 110VAC 500ms, 30ms, 120ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Overvoltage protection | Turn off the output when the output voltage > 135% Restart and recover after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -20℃~+70℃; 20%~90RH | |||
Storage temperature and humidity | -40℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 22.5*90*100mm | |||
Net weight/gross weight | 170/185g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
output | DC voltage | 5V | 12V | 15V | 24V |
Rated current | 3A | 1.67A | 1.34A | 1A | |
rated power | 15W | 20W | 20W | 24W | |
Ripple and Noise① | <80mV | <120mV | <120mV | <150mV | |
Voltage accuracy | ±2% | ±1% | ±1% | ±1% | |
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1% | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >77% | >81% | >81% | >84% | |
Working current | <0.55A 110VAC <0.35A 220VAC | ||||
electric shock | 110VAC 35A, 220VAC 70A | ||||
Start, rise, hold time | 1000ms, 30ms, 25ms: 110VAC 500ms, 30ms, 120ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Overvoltage protection | Turn off the output when the output voltage > 135% Restart and recover after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -20℃~+70℃; 20%~90RH | |||
Storage temperature and humidity | -40℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 22.5*90*100mm | |||
Net weight/gross weight | 170/185g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 6A | 3.33A | 1.7A | 0.83A | |
rated power | 30W | 40W | 40.8W | 39.8W | |
Ripple and Noise① | <80mV | <120mV | <150mV | <200mV | |
Voltage accuracy | ±2% | ±1% | ±1% | ±1% | |
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1% | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >86% | >88% | >88% | |
Working current | <1.1A 110VAC <0.7A 220VAC | ||||
electric shock | 110VAC 35A, 220VAC 70A | ||||
Start, rise, hold time | 500ms, 30ms, 25ms: 110VAC 500ms, 30ms, 120ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Overvoltage protection | Turn off the output when the output voltage > 135% Restart and recover after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -20℃~+70℃; 20%~90RH | |||
Storage temperature and humidity | -40℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 40*90*100mm | |||
Net weight/gross weight | 300/325g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 5V | 12V | 24V | 48V |
Rated current | 10A | 5A | 2.5A | 1.25A | |
rated power | 50W | 60W | 60W | 60W | |
Ripple and Noise① | <80mV | <120mV | <150mV | <200mV | |
Voltage accuracy | ±2% | ±1% | ±1% | ±1% | |
Output voltage regulation range | ±10% | ||||
Load Regulation | ±1.5% | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±1% | ||||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |||
Efficiency (Typical) ② | >78% | >86% | >88% | >87% | |
Working current | <1.8A 110VAC <1A 220VAC | ||||
electric shock | 110VAC 35A, 220VAC 70A | ||||
Start, rise, hold time | 500ms, 30ms, 25ms: 110VAC 500ms, 30ms, 120ms: 220VAC | ||||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | |||
Overvoltage protection | Turn off the output when the output voltage > 135% Restart and recover after the abnormal condition is removed | ||||
surroundings | Working temperature and humidity | -20℃~+70℃; 20%~90RH | |||
Storage temperature and humidity | -40℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | |||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 40*90*100mm | |||
Net weight/gross weight | 330/350g | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | |||
output | DC voltage | 12V | 24V | 48V |
Rated current | 7.5A | 4A | 2A | |
rated power | 90W | 96W | 96W | |
Ripple and Noise① | <120mV | <150mV | <200mV | |
Voltage accuracy | ±1% | ±1% | ±1% | |
Output voltage regulation range | ±10% | |||
Load Regulation | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±1% | |||
enter | voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (Typical) ② | >83% | >86% | >87% | |
power factor | PF≥0.95/230VAC PF≥0.98/115VAC (full load) | |||
Working current | <1.3A 110VAC <0.8A 220VAC | |||
electric shock | 110VAC 35A, 220VAC 70A | |||
Start, rise, hold time | 3000ms, 50ms, 20ms: 110VAC 3000ms, 50ms, 50msms: 220VAC | |||
Protect | Overload protection | 105%-150% Type: Protection Mode: Hiccup Mode Automatic recovery after abnormal condition is removed | ||
Overvoltage protection | Turn off the output when the output voltage > 135% Restart and recover after the abnormal condition is removed | |||
Over temperature protection | Turn off the output when the temperature is greater than 85°C, restart after the temperature returns to normal | |||
surroundings | Working temperature and humidity | -20℃~+70℃; 20%~90RH | ||
Storage temperature and humidity | -40℃~+85℃; 10%~95RH | |||
Safety | Withstand voltage | Input-Output: 3KVAC Input-Ground: 1.5KVAC Output-Ground: 0.5KVAC for 1 minute | ||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | |||
other | size | 55*90*100mm | ||
Net weight/gross weight | 420/450g | |||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth. ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear regulation and load regulation Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |