technical parameter:
project | Technical indicators | ||||
output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 80 | 40 | 27.5A | 20 | |
rated power | 960W | 960W | 990W | 960W | |
Ripple and Noise① | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load Regulation | <± 1.2 % | <± 1 % | <± 0.5 % | <± 0.5 % | |
Linear adjustment rate | <±1% | ||||
enter | voltage range | 180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||
Efficiency ( Typical ) ② | >82% | >84% | >86% | >86% | |
Working current | 220VAC: 60A | ||||
electric shock | <10A 230VAC | ||||
Start, rise, hold time | 200ms, 50ms, 20ms: 230VAC | ||||
Protect | Overload protection | 105%-135% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||
Overvoltage protection | Turn off the output when ≥115%-145% | ||||
Short circuit protection | close output | ||||
Over temperature protection | RTH3: The fan is always running, and the output is turned off at ≥90°C | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <6mA at 1.5KVAC | ||||
leakage current | Input-output <1.5mA at 220VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 291*132*68mm | |||
Net weight/gross weight | 2kg/2.1kg | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 120A | 60A | 42A | 31.5 | |
rated power | 1440W | 1440W | 1512W | 1512W | |
Ripple and Noise① | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load Regulation | <±1.2% | <±1% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±1% | ||||
enter | voltage range | 180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||
Efficiency (Typical) ② | >85% | >88% | >88% | >90% | |
Working current | 220VAC: 13.5A | ||||
electric shock | 60A 230VAC | ||||
Start, rise, hold time | 2000ms, 50ms, 20ms: 230VAC | ||||
Protect | Overload protection | 105%-135% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||
Over temperature protection | RTH3: The fan is always running, and the output is turned off at ≥90°C | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <6mA at 1.5KVAC | ||||
leakage current | Input-output <1.5mA at 220VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 258*158*87mm | |||
Net weight/gross weight | 3kg/3.1kg | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 150A | 80A | 55.5A | 41.6A | |
rated power | 1800W | 1920W | 1998W | 1996W | |
Ripple and Noise① | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load Regulation | <±1.2% | <±1% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±1% | ||||
enter | voltage range | 180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||
Efficiency (Typical) ② | >85% | >88% | >89% | >90% | |
Working current | 220VAC: 18A | ||||
electric shock | 60A 230VAC | ||||
Start, rise, hold time | 2000ms, 50ms, 20ms: 230VAC | ||||
Protect | Overload protection | 105%-135% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||
Over temperature protection | RTH3: The fan is always running, and the output is turned off at ≥90°C | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <6mA at 1.5KVAC | ||||
leakage current | Input-output <1.5mA at 220VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 258*158*87mm | |||
Net weight/gross weight | 3kg/3.1kg | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |
project | Technical indicators | ||||
output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 200A | 120A | 83A | 62.4A | |
rated power | 2400W | 2880W | 2988W | 2995W | |
Ripple and Noise① | <240mV | <240mV | <360mV | <480mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load Regulation | <±1% | <±1% | <±1% | <±1% | |
Linear adjustment rate | <±1% | ||||
enter | voltage range | 180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||
Efficiency (Typical) ② | >86% | >88% | >89% | >90% | |
Working current | 220VAC: 23A | ||||
electric shock | 60A 230VAC | ||||
Start, rise, hold time | 2000ms, 50ms, 20ms: 230VAC | ||||
Protect | Overload protection | 105%-135% Type: constant current output +VO drops to under-voltage point, cut off output reset: re-power on | |||
Over temperature protection | RTH3: The fan is always running, and the output is turned off at ≥90°C | ||||
surroundings | Working temperature and humidity | -10℃~+50℃; 20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃; 10%~95RH | ||||
Safety | Withstand voltage | Input-Output: 1.5KVAC Input-Case: 1.5kVAC Output-Case: 0.5KVAC for 1 minute | |||
leakage current | Input-output <6mA at 1.5KVAC | ||||
leakage current | Input-output <2mA at 240VAC | ||||
Isolation resistance | Input-Output, Input-Case, Output-Case: 500VDC/100MΩ | ||||
other | size | 312×190×95mm | |||
Net weight/gross weight | 6Kg/6.2Kg | ||||
Remark | ①Ripple and noise measurement method: use a 12" twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at 20MHz bandwidth ②The efficiency is tested under the input voltage of 230VAC, the rated load, and the ambient temperature of 25℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear Regulation Test Method: Test from Low Voltage to High Voltage at Rated Load Load regulation test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters. |