产品概述:42U cabinet models with capacity up to 300 KW provide high efficiency and overload capacity, +Power is a true modular UPS system that can easily expand UPS capa···
42U cabinet type with capacity up to 300 KW
Offering high efficiency and overload capability, +Power is a true modular UPS system that can easily expand UPS capacity up to 300KW. Modular design is applied to power modules, STS modules and battery modules. Modular design for easy maintenance and replacement reduces mean time to repair (MTTR).
main feature
●N+1 or N+R1 parallel redundant application design increases system flexibility, stability and security
●High-efficiency double-conversion online UPS system
●Output power factor 1.0
●Modular design, easy to expand, update and maintain, which can reduce after-sale maintenance costs
●STS modules use redundant power supplies for highly reliable operation
●The charging current is adjustable
●The number of battery cells is adjustable
●Strong overload capacity
5.7” LCD graphic design, the display is more direct and clear
●Optional 10-touch color LCD screen
Product Specifications
MODEL | +Power 30U-90HV | +Power 42U-120HV | +Power 30U-80-20KHV | +Power 30U-120HV | +Power 30U-120-20KHV | +Power 30U-180HV | |
Cabinet capacity | 90KW | 120KW | 120KW or 80KW | 180KW or 120KW | |||
phase | 3-phase in/3-phase out | ||||||
Maximum battery pack size | 3 | 5 | - | ||||
Battery Type | Built-in Battery | External Battery | |||||
maximum power module | 3 | 4 | 6 | ||||
Power Module Capacity | 30 KVA / 30 KW | 30 KVA / 30 KW or 20 KVA / 20KW | |||||
ENTER | |||||||
voltage range | 305~478 VAC at 70%-100% load; 208~478VAC for <70% load | ||||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
Frequency Range | 40Hz ~70Hz | ||||||
Rated frequency | 50/60 Hz (Auto sensing) | ||||||
power factor | > 0.99 at 100% load, >0.98 at 50% load | ||||||
Harmonic Distortion (THDi) | < 3% @ 100% load | ||||||
OUTPUT | |||||||
Rated frequency | 50/60Hz | ||||||
overload capacity | 1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150% | ||||||
Voltage regulation (steady state) | ≦ ±1% Typical (balanced load); ≦ ±2% Typical (unbalanced load) | ||||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
efficiency | Up to 94.5% | ||||||
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) | ||||||
Frequency range (sync range) | 46Hz~54Hz or 56Hz~64Hz | ||||||
BATTERIES AND CHARGERS | |||||||
float voltage | 2.25V/Cell | ||||||
boost charging voltage | 2.35V/Cell | ||||||
Maximum charging current | 8A | 8A for 30KW power module; 6A for 20KW power module | |||||
maximum voltage | +/- 240V (12V x 40 Pcs) | ||||||
Rated voltage | +/- 216V (12V x 36 Pcs) | ||||||
Temperature compensation | Yes | ||||||
Minimum voltage | +/- 192V (12V x 32 Pcs) | ||||||
SURROUNDINGS | |||||||
Altitude | <1000m for Nominal power | ||||||
IP class | IP 20 | ||||||
Operating temperature | 0~40℃ | ||||||
Working humidity | 0~95% non-condensing | ||||||
PHYSICS | |||||||
Cabinet Dimensions, D X W X H (mm) | 1100 x 600 x 1475 | 1100 x 600 x 2010 | 1100 x 600 x 1475 | ||||
Net weight (kg) | 675 | 932 | 335 or 333 | 437.5 or 434.5 | |||
MANAGE | |||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC | ||||||
STANDARD | |||||||
Safety verification | IEC/EN 60950-1; IEC/EN 62040-1 |
Model | +Power 42U-200-20KHV | +Power 42U-210HV | +Power 42U-300HV | |
Cabinet capacity | 200KW | 210KW | 300KW | |
phase | 3-phase in/3-phase out | |||
Maximum battery pack size | - | |||
Battery Type | External Battery | |||
maximum power module | 10 | 8 | 10 | |
Power Module Capacity | 20KW | 30 KVA / 30 KW | ||
ENTER | ||||
voltage range | 305~478 VAC at 70%-100% load; 208~478VAC for <70% load | |||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||
Frequency Range | 40Hz ~70Hz | |||
Rated frequency | 50/60 Hz (Auto sensing) | |||
power factor | > 0.99 at 100% load, >0.98 at 50% load | |||
Harmonic Distortion (THDi) | < 3% @ 100% load | |||
OUTPUT | ||||
Rated frequency | 50/60Hz | |||
overload capacity | 1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150% | |||
Voltage regulation (steady state) | ≦ ±1% Typical (balanced load); ≦ ±2% Typical (unbalanced load) | |||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||
efficiency | Up to 94.5% | |||
Harmonic Distortion | ≦ 2% THD (Linear Load); ≦ 4% THD (Non-linear Load) | |||
Frequency range (sync range) | 46Hz~54Hz or 56Hz~64Hz | |||
BATTERIES AND CHARGERS | ||||
float voltage | 2.25V/Cell | |||
boost charging voltage | 2.35V/Cell | |||
Maximum charging current | 6A | 8A | ||
maximum voltage | +/- 240V (12V x 40 Pcs) | |||
Rated voltage | +/- 216V (12V x 36 Pcs) | |||
Temperature compensation | Yes | |||
Minimum voltage | +/- 192V (12V x 32 Pcs) | |||
SURROUNDINGS | ||||
Altitude | <1000m for Nominal power | |||
IP class | IP 20 | |||
Operating temperature | 0~40℃ | |||
Working humidity | 0~95% non-condensing | |||
PHYSICS | ||||
Cabinet Dimensions, D X W X H (mm) | 1100 x 600 x 2010 | |||
Net weight (kg) | 611 | 549 | 620 | |
MANAGE | ||||
Optional SNMP | Power management from SNMP manager and web browser | |||
Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC | |||
STANDARD | ||||
Safety verification | IEC/EN 60950-1; IEC/EN 62040-1 |