Galleon II 3P/3P 10K-80K

Galleon II 3P/3P 10K-80K

产品概述:Output power factor 1, three-level topology, support for shared battery pack Galleon II 3P/3P 10K-80K provides output power factor up to 1.0, providing higher p···

产品简介

Output power factor 1, three-level topology, support shared battery pack

The Galleon II 3P/3P 10K-80K offers up to 1.0 output power factor, delivering higher performance and efficiency for critical applications. This powerful in-line series integrates true double conversion design, DSP technology and active input power factor correction design to ensure better output voltage, power quality and performance at all times. The LCD display provides real-time UPS status for enhanced flexibility to meet the power demands of growing IT and network environments.

main feature

●Real double conversion online UPS system

●DSP technology ensures high performance

●Output power factor 1.0

●Active power factor correction

●50/60hz frequency conversion mode

●ECO energy saving operation function

●Emergency power off function (EPO)

●Optional parallel function

●Intelligent charging design to optimize battery performance

●Built-in maintenance bypass switch

●The number of battery cells is adjustable

MODELGalleon II-3/3 10K(L)Galleon II-3/3 15K(L)Galleon II-3/3 20K(L)Galleon II-3/3 30K(L)Galleon II-3/3 40K(L)Galleon II-3/3 60KL
capacity10 KVA / 10 KW15 KVA / 15 KW20KVA/20KW30 KVA / 30 KW40 KVA / 40 KW60 KVA / 60 KW
phase3-phase in/3-phase out
Parallel capabilityup to 6 units in parallel
ENTER
voltage range190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Rated voltage3 x 380/ 400/ 415 VAC ( 3 Ph+N)
Frequency Range40~70 Hz
power factor≧ 0.99 @ 100% load
OUTPUT
The output voltage3 x 360*/380/400/415 (3 Min +N)3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Voltage Mode)± 1%
Frequency Range (Battery Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
transfer timeAC mode is battery modezero
transfer timeInverter to Bypasszero
Waveform (Battery Mode)Pure Sine Wave
Current crest ratio3:1 (max.)
Harmonic Distortion≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Frequency range (sync range)46~54Hz or 56~64Hz
overloadCommunication mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
overloadbattery mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
battery mode96%
ECO mode99%
Communication mode96%
BATTERY
long extension machineModule charging voltage+/-136.5 VDC ± 10%+/-13.65V*N (N = 16~20)+/- 13.65V*N (N=16~20)
long extension machineModule charging current (max)1A ~ 12A (Adjustable)2A~24A (Adjustable)
long extension machinenumber of modules(10+10) pcs(16+16) ~ (20+20) pcs (Adjustable)
long extension machineModular battery typeDepending on the capacity of external batteries
Standard machineCharger voltage+/-136.5 VDC ± 10%+/-218 VDC ± 10%N/A
Standard machineCharge current (max)1A~12A (Adjustable)N/A
Standard machineTypical charging time9 hours recover to 90% capacityN/A
Standard machinequantity(10+10)pcs(16+16)pcs(16+16)pcs x 2 stringsN/A
Standard machineBattery Type12V/9Ah12V/7Ah12V/9AhN/A
INDEX
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
SURROUNDINGS
Operating temperature0~40°C
Working humidity<95% and non-condersing
noise levelLess than 55dB @ 1 MeterLess than 58dB @ 1 MeterLess than 65dB @ 1 MeterLess than 70dB @ 1 Meter
PHYSICS
Standard machineNet weight/kg124139225250N/A
Standard machineDimensions, D X W X H (mm)630 x 250 x 826815 x 300 x 1000N/A
long extension machineNet weight/kg28436067108
long extension machineDimensions, D X W X H (mm)630 x 250 x 826815 x 300 x 1000790 x 360 x 1010
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC
ModelGalleon II-3/3 80KL
capacity80KVA / 80KW
phase3-phase in/3-phase out
Parallel capabilityup to 6 units in parallel
ENTER
voltage range190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Rated voltage3 x 380/ 400/ 415 VAC ( 3 Ph+N)
Frequency Range40~70 Hz
power factor≧ 0.99 @ 100% load
OUTPUT
The output voltage3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Voltage Mode)± 1%
Frequency Range (Battery Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
transfer timeAC mode is battery modezero
transfer timeInverter to Bypasszero
Waveform (Battery Mode)Pure Sine Wave
Current crest ratio3:1 (max.)
Harmonic Distortion≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Frequency range (sync range)46~54Hz or 56~64Hz
overloadCommunication mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
overloadbattery mode100-110% for 60 min, 110-125% for 10 min, >150% immediately
EFFICIENCY
battery mode96%
ECO mode99%
Communication mode96%
BATTERY
long extension machineModule charging voltage+/- 13.65V*N (N=16~20)
long extension machineModule charging current (max)2A~24A (Adjustable)
long extension machinenumber of modules(16+16) ~ (20+20) pcs (Adjustable)
long extension machineModular battery typeDepending on the capacity of external batteries
Standard machineCharger voltageN/A
Standard machineCharge current (max)N/A
Standard machineTypical charging timeN/A
Standard machinequantityN/A
Standard machineBattery TypeN/A
INDEX
LCD panelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
SURROUNDINGS
Operating temperature0~40°C
Working humidity<95% and non-condersing
noise levelLess than 75dB @ 1 Meter
PHYSICS
Standard machineNet weight/kgN/A
Standard machineDimensions, D X W X H (mm)N/A
long extension machineNet weight/kg113
long extension machineDimensions, D X W X H (mm)790 x 360 x 1010
MANAGE
Optional SNMPPower management from SNMP manager and web browser
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, and MAC


Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)