Galleon III 3P/3P 30KL-200KL

Galleon III 3P/3P 30KL-200KL

产品概述:Pluggable power module Galleon III 3P / 3P UPS from 30K to 200K, pluggable power module design and front maintenance design, simplify maintenance, and equipped ···

产品简介

Pluggable Power Modules

Galleon III 3P / 3P UPS from 30K to 200K, plug-in power module design and front maintenance design, simplify maintenance, and equipped with Power walk in function, reduce the inrush current of system startup, reduce the generator capacity under parallel system demand.

main feature

●DSP technology ensures high efficiency

●Output power factor 1.0

●Plugable simple power module design

●The design of access from the front panel makes the maintenance work more convenient

● Active power factor correction for each phase deviation

●Emergency shutdown function (EPO)

●Dual AC input

●Applicable to general batteries, up to 4 units can be run in parallel

●Power walk in function, reduce the impact on the generator under the parallel system

● Compatible generator

●The number of batteries is adjustable

●Provide two-way maintenance

3-level scalable charging design to optimize battery performance

●Optional isolation transformer to provide complete isolation and suppression of common mode noise

Product Specifications

MODELGalleon III 3/3-30K(L)Galleon III 3/3-60KLGalleon III 3/3-100KLGalleon III 3/3-120KLGalleon III 3/3-180KLGalleon III 3/3-200KL
capacity30KVA / 30KW60 KVA / 60 KW100 KVA / 100 KW120KVA / 120KW180KVA / 180KW200 KVA / 200 KW
phaseThree phase in/three phase out
Parallel function4
ENTER
voltage range110-300 VAC @ 50% load; 176-276 VAC @ 100% load
Rated voltage3 x 380/400/415VAC (3Ph+N)
Frequency Range40~70Hz
power factor≧ 0.99 @ 100% load
Harmonic Distortion (THDi)< 4% full linear load
OUTPUT
The output voltage3 x 360*/380/400/415VAC (3Ph+N)
Frequency Range (Battery Mode)50/60 Hz ± 1%
transfer timeAC Mode to Battery Mode0
transfer timeInverter to Bypass0
Waveform (Battery Mode)pure sine wave
Current crest ratio3:1 (max.)
Harmonic Distortion≦2% THD (linear load) ≦5% THD (non-linear load)
Frequency range (sync range)46~54Hz or 56~64Hz
AC Voltage Regulation (Battery Mode)± 1%
overload capacity100-110% for 60 minutes, 111-125% for 10 minutes, 126%~150% for 1 minute; >150% for 400ms
EFFICIENCY
battery mode95%
Communication mode96%
ECO mode99%
BYPASS
overload capacity> 130% for 1 minute (preset value) Continuous operation until circuit breaker protection (optional)
Rated voltage3 x 380/400/415VAC (3Ph+N)
voltage range305VAC~457VAC
Frequency range (sync range)46~54Hz or 56~64Hz
BATTERY
standard machineCharger voltage(16+16) x 2N/A
standard machineCharge current (max)2AN/A
standard machinequantity+/- 13.65 VDC * N ± 1% (N = 16~20)N/A
standard machineBattery Type12V/7AhN/A
long flightCharger voltage+/-13.65V*N (N = 16~20)+/-13.65V*N (N = 16~20)
long flightCharge current (max)1-12A, adjustable1-18A (adjustable)2-36A (Adjustable)3-54A (Adjustable)
long flightquantity32~40 pieces (adjustable)
long flightBattery TypeMatch multiple battery boxes according to the actual application
ALARM
battery modesound every 4 seconds
low powersound every second
FaultContinuous sound
overloadTwice per second
SURROUNDINGS
Altitude0 ~ 1500m when fully loaded
Operating temperature0-40°C
Working humidity<95% (non-condensing)0~95% RH @ 0- 40°C (non-condensing)
noise levelLess than 65dB @ 1mLess than 70dB @ 1m
PHYSICS
standard machineNet weight/kg815 x 300 x 1000N/A
standard machineDimensions, D X W X H (mm)207N/A
long flightNet weight/kg5674250340345
long flightDimensions, D X W X H (mm)815 x 300 x 1000974 x 600 x 1600
MANAGE
Optional SNMPPower management via SNMP manager and web browser
Smart RS-232/USBSupport Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, MAC
SHOW DESCRIPTION
7-inch touch-sensitive color LCD panelUPS status, load levels, battery levels, input/output voltages, discharge timers and fault conditions



Excel Energy Co., Ltd.

0577-62789660

(联系电话 7×24)