Giant 3P/3P 10KVA-200KVA

Giant 3P/3P 10KVA-200KVA

产品概述:On-line UPS with built-in isolation transformer Built-in isolation transformer, Giant series will eliminate common mode noise and provide reliable isolated powe···

产品简介

On-line UPS with built-in isolation transformer

With built-in isolation transformers, the Giant series will eliminate common mode noise and provide reliable isolated power for critical equipment.

main feature

●Real double conversion online UPS system

●DSP technology ensures high performance

●Built-in isolation transformer design

●Industrial grade design for various harsh conditions

●Intelligent battery management to extend battery life

●Independent air duct design can run continuously in harsh environment

●The number of battery cells is adjustable

●Dual input selection

●Up to 4 units can be operated in parallel

●Diversified communication interfaces

●Optional 7-touch color LCD screen

●Support input out-of-phase rectification and no N-line input

Product Specifications

MODELGiant 10KGiant 15KGiant 20KGiant 30KGiant 40KGiant 60K
capacity10 KVA / 8 KW15 KVA / 12 KW20KVA/16KW30 KVA / 24 KW40 KVA / 32 KW60 KVA / 48 KW
ENTER
Rated voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
acceptable voltage range165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
frequency50 Hz/60 Hz ± 10%
INVERTER
admissiblepower factor0.6~1 (inductive or capacitive)
admissibleCrest factor3:1
admissibleoverload110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
LimitingHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Dynamic recovery time3 cycles at 90 % of the static value
frequency50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Unbalanced output voltage @ 100% unbalanced load<1%
maximum sync speed± 1Hz/s
Rated voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
phase120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
accurateStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Total Harmonic Distortion (THDv)<2% (Linear Load); <5% (Non-linear Load)
waveformPure Sine Wave
STATIC BYPASS
activation criteriaMicroprocessor control
Overload allowed0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
frequency50 Hz/60 Hz ± 10%
retransferAutomatic after alarm clear
transfer timeZero
divert to bypassImmediate, for overloads above 160%
typeSolid state
Voltage176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
MAINTENANCE BYPASS
frequency50 Hz/60 Hz
overall efficiencybattery mode90%91%92%
overall efficiencyline mode89%90%91%
typeWithout interruption
Voltage3 x 400VAC(3Ph+N)
BATTERIES AND CHARGERS
charging methodCC/CV
Charging voltage432 VDC (Based on 32pcs batteries)
Rated battery voltage384 VDC (Based on 32pcs batteries)
precision± 1%
Battery type and quantity12 VDC x 32 pcs (29~32 pcs adjustable)
recharging currentDefault 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time).Default 10A; Maximum 40A; 5A@ full load
PHYSICS
Dimensions, D X W X H (mm)656 x 405 x 817656 x 405 x 941821 x 432 x 1159
Net weight (kg)118120145193278365
ModelGiant 80KGiant 100KGiant 120KGiant 160KGiant 200K
capacity80KVA/64KW100 KVA / 80 KW120 KVA / 96 KW160 KVA / 128 KW200 KVA / 160 KW
ENTER
Rated voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
acceptable voltage range165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph)
frequency50 Hz/60 Hz ± 10%
INVERTER
admissiblepower factor0.6~1 (inductive or capacitive)
admissibleCrest factor3:1
admissibleoverload110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms
LimitingHigh overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
Dynamic recovery time3 cycles at 90 % of the static value
frequency50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz
Unbalanced output voltage @ 100% unbalanced load<1%
maximum sync speed± 1Hz/s
Rated voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
phase120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load)
accurateStationary: ±1%; Transitory: ±5% (load variations 100-0-100%)
Total Harmonic Distortion (THDv)<2% (Linear Load); <5% (Non-linear Load)
waveformPure Sine Wave
STATIC BYPASS
activation criteriaMicroprocessor control
Overload allowed0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min
frequency50 Hz/60 Hz ± 10%
retransferAutomatic after alarm clear
transfer timeZero
divert to bypassImmediate, for overloads above 160%
typeSolid state
Voltage176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph)
MAINTENANCE BYPASS
frequency50 Hz/60 Hz
overall efficiencybattery mode93%
overall efficiencyline mode92%
typeWithout interruption
Voltage3 x 400VAC(3Ph+N)
BATTERIES AND CHARGERS
charging methodCC/CV
Charging voltage432 VDC (Based on 32pcs batteries)
Rated battery voltage384 VDC (Based on 32pcs batteries)
precision± 1%
Battery type and quantity12 VDC x 32 pcs (29~32 pcs adjustable)
recharging currentDefault 10A; Maximum 40A; 5A@ full load
PHYSICS
Dimensions, D X W X H (mm)975 x 554 x 1286975 x 635 x 13261051x705x1646
Net weight (kg)471573650760790



Excel Energy Co., Ltd.