On-line UPS with built-in isolation transformer
With built-in isolation transformers, the Giant series will eliminate common mode noise and provide reliable isolated power for critical equipment.
main feature
●Real double conversion online UPS system
●DSP technology ensures high performance
●Built-in isolation transformer design
●Industrial grade design for various harsh conditions
●Intelligent battery management to extend battery life
●Independent air duct design can run continuously in harsh environment
●The number of battery cells is adjustable
●Dual input selection
●Up to 4 units can be operated in parallel
●Diversified communication interfaces
●Optional 7-touch color LCD screen
●Support input out-of-phase rectification and no N-line input
Product Specifications
MODEL | Giant 10K | Giant 15K | Giant 20K | Giant 30K | Giant 40K | Giant 60K | |
capacity | 10 KVA / 8 KW | 15 KVA / 12 KW | 20KVA/16KW | 30 KVA / 24 KW | 40 KVA / 32 KW | 60 KVA / 48 KW | |
ENTER | |||||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
acceptable voltage range | 165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph) | ||||||
frequency | 50 Hz/60 Hz ± 10% | ||||||
INVERTER | |||||||
admissible | power factor | 0.6~1 (inductive or capacitive) | |||||
admissible | Crest factor | 3:1 | |||||
admissible | overload | 110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms | |||||
Limiting | High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit | ||||||
Dynamic recovery time | 3 cycles at 90 % of the static value | ||||||
frequency | 50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz | ||||||
Unbalanced output voltage @ 100% unbalanced load | <1% | ||||||
maximum sync speed | ± 1Hz/s | ||||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
phase | 120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load) | ||||||
accurate | Stationary: ±1%; Transitory: ±5% (load variations 100-0-100%) | ||||||
Total Harmonic Distortion (THDv) | <2% (Linear Load); <5% (Non-linear Load) | ||||||
waveform | Pure Sine Wave | ||||||
STATIC BYPASS | |||||||
activation criteria | Microprocessor control | ||||||
Overload allowed | 0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min | ||||||
frequency | 50 Hz/60 Hz ± 10% | ||||||
retransfer | Automatic after alarm clear | ||||||
transfer time | Zero | ||||||
divert to bypass | Immediate, for overloads above 160% | ||||||
type | Solid state | ||||||
Voltage | 176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph) | ||||||
MAINTENANCE BYPASS | |||||||
frequency | 50 Hz/60 Hz | ||||||
overall efficiency | battery mode | 90% | 91% | 92% | |||
overall efficiency | line mode | 89% | 90% | 91% | |||
type | Without interruption | ||||||
Voltage | 3 x 400VAC(3Ph+N) | ||||||
BATTERIES AND CHARGERS | |||||||
charging method | CC/CV | ||||||
Charging voltage | 432 VDC (Based on 32pcs batteries) | ||||||
Rated battery voltage | 384 VDC (Based on 32pcs batteries) | ||||||
precision | ± 1% | ||||||
Battery type and quantity | 12 VDC x 32 pcs (29~32 pcs adjustable) | ||||||
recharging current | Default 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time). | Default 10A; Maximum 40A; 5A@ full load | |||||
PHYSICS | |||||||
Dimensions, D X W X H (mm) | 656 x 405 x 817 | 656 x 405 x 941 | 821 x 432 x 1159 | ||||
Net weight (kg) | 118 | 120 | 145 | 193 | 278 | 365 |
Model | Giant 80K | Giant 100K | Giant 120K | Giant 160K | Giant 200K | |
capacity | 80KVA/64KW | 100 KVA / 80 KW | 120 KVA / 96 KW | 160 KVA / 128 KW | 200 KVA / 160 KW | |
ENTER | ||||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||||
acceptable voltage range | 165VAC ~ 280VAC (Ph-N); 285VAC ~ 485VAC (Ph-Ph) | |||||
frequency | 50 Hz/60 Hz ± 10% | |||||
INVERTER | ||||||
admissible | power factor | 0.6~1 (inductive or capacitive) | ||||
admissible | Crest factor | 3:1 | ||||
admissible | overload | 110% ~ 150% 10 min ~ 60 sec; 150% ~ 160% 60 sec~ 200ms; >160% 200ms | ||||
Limiting | High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit | |||||
Dynamic recovery time | 3 cycles at 90 % of the static value | |||||
frequency | 50/60 Hz synchronised ±1 %; With mains absent ±0.1 Hz | |||||
Unbalanced output voltage @ 100% unbalanced load | <1% | |||||
maximum sync speed | ± 1Hz/s | |||||
Rated voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | |||||
phase | 120º ±1% (balanced load); 120º ±2% (imbalances 50% of the load) | |||||
accurate | Stationary: ±1%; Transitory: ±5% (load variations 100-0-100%) | |||||
Total Harmonic Distortion (THDv) | <2% (Linear Load); <5% (Non-linear Load) | |||||
waveform | Pure Sine Wave | |||||
STATIC BYPASS | ||||||
activation criteria | Microprocessor control | |||||
Overload allowed | 0% ~ 150% continuous working; 150% ~ 180% 60 min~5 min; >180% 5 min | |||||
frequency | 50 Hz/60 Hz ± 10% | |||||
retransfer | Automatic after alarm clear | |||||
transfer time | Zero | |||||
divert to bypass | Immediate, for overloads above 160% | |||||
type | Solid state | |||||
Voltage | 176VAC~264VAC (Ph-N); 304VAC~456VAC (Ph-Ph) | |||||
MAINTENANCE BYPASS | ||||||
frequency | 50 Hz/60 Hz | |||||
overall efficiency | battery mode | 93% | ||||
overall efficiency | line mode | 92% | ||||
type | Without interruption | |||||
Voltage | 3 x 400VAC(3Ph+N) | |||||
BATTERIES AND CHARGERS | ||||||
charging method | CC/CV | |||||
Charging voltage | 432 VDC (Based on 32pcs batteries) | |||||
Rated battery voltage | 384 VDC (Based on 32pcs batteries) | |||||
precision | ± 1% | |||||
Battery type and quantity | 12 VDC x 32 pcs (29~32 pcs adjustable) | |||||
recharging current | Default 10A; Maximum 40A; 5A@ full load | |||||
PHYSICS | ||||||
Dimensions, D X W X H (mm) | 975 x 554 x 1286 | 975 x 635 x 1326 | 1051x705x1646 | |||
Net weight (kg) | 471 | 573 | 650 | 760 | 790 |