产品概述:On-line UPS with built-in isolation transformer Built-in isolation transformer, Giant series will eliminate common mode noise and provide reliable isolated powe···
On-line UPS with built-in isolation transformer
With built-in isolation transformers, the Giant series will eliminate common mode noise and provide reliable isolated power for critical equipment.
main feature
DSP control true online double conversion
●Output power factor 0.9, customized up to 1.0
Galvanic isolation eliminates common mode noise providing the cleanest power supply in the harshest conditions
Conformal coating ensures operational stability and safety in critical environments
●Standard IP31 protection, optional IP42, withstand harsh environments
●Maintain long-term operation of all types of loads at low input voltage
●Redundant design to ensure product reliability
●Temperature compensation extends battery life
●Feedback protection ensures safe operation
7 touch color LCD with customized control settings and accessible UPS information data
●Accept dual power input
● Parallel capability of up to 4 units
●Optional 40kA surge protection module
● Provide optional FOOTMASTER casters
Product Specifications
MODEL | Giant II 10K | Giant II 15K | Giant II 20K | Giant II 30K | Giant II 40K | Giant II 60K | |
CAPACITY | 10KVA/9KW | 15KVA/13.5KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | |
ENTER | |||||||
Rated voltage | 380VAC/400VAC/415VAC | ||||||
acceptable voltage range | 304VAC ~ 456VAC | ||||||
frequency | 50Hz ± 10% | ||||||
Rectifier type | 6 pulse | ||||||
Main input and bypass input | Supports dual inputs | ||||||
TVSS | 40kA (optional) | ||||||
OUTPUT | |||||||
power factor | 110% continuous running; 125% for 10 min; >150% for 1 min | ||||||
overload capacity | 0.9, customized up to 1.0 | ||||||
Rated output voltage | 380VAC/400VAC/415VAC | ||||||
Output voltage regulation | ±1% | ||||||
BYPASS | |||||||
Input voltage range | 285VAC ~ 475VAC | ||||||
Rated voltage | 380VAC/400VAC/415VAC | ||||||
BATTERY | |||||||
battery voltage | 384 VDC (Adjustable) | ||||||
Cold start | Yes | ||||||
SURROUNDINGS | |||||||
Operating temperature | 0~ 50°C | ||||||
altitude | 1000m | ||||||
Storage temperature | -25°C ~ 55°C | ||||||
humidity | 0~95% (non-condensing) | ||||||
PHYSICS | |||||||
Dimensions, D X W X H (mm) | 656 x 405 x 817 | 656 x 405 x 941 | 821 x 432 x 1159 | 800 x 1200 x 1800 | |||
Net weight (kg) | 120 | 145 | 193 | 278 | 365 | 471 | |
IP protection | IP31 (default), IP42 (optional) | ||||||
MANAGE | |||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
dry contact | 5 outputs and 4 inputs | ||||||
Modbus RS-232/RS485 | Supports Windows® family, Linux and MAC | ||||||
STANDARD | |||||||
Safety | IEC62040-1-2017 |
Model | Giant II 80K | Giant II 100K | Giant II 120K | Giant II 160K | |
CAPACITY | 80KVA/72KW | 100KVA/90KW | 120KVA/108KW | 160KVA/144KW | |
ENTER | |||||
Rated voltage | 380VAC/400VAC/415VAC | ||||
acceptable voltage range | 304VAC ~ 456VAC | ||||
frequency | 50Hz ± 10% | ||||
Rectifier type | 6 pulse | ||||
Main input and bypass input | Supports dual inputs | ||||
TVSS | 40kA (optional) | ||||
OUTPUT | |||||
power factor | 110% continuous running; 125% for 10 min; >150% for 1 min | ||||
overload capacity | 0.9, customized up to 1.0 | ||||
Rated output voltage | 380VAC/400VAC/415VAC | ||||
Output voltage regulation | ±1% | ||||
BYPASS | |||||
Input voltage range | 285VAC ~ 475VAC | ||||
Rated voltage | 380VAC/400VAC/415VAC | ||||
BATTERY | |||||
battery voltage | 384 VDC (Adjustable) | ||||
Cold start | Yes | ||||
SURROUNDINGS | |||||
Operating temperature | 0~ 50°C | ||||
altitude | 1000m | ||||
Storage temperature | -25°C ~ 55°C | ||||
humidity | 0~95% (non-condensing) | ||||
PHYSICS | |||||
Dimensions, D X W X H (mm) | 800 x 1200 x 1800 | 975 x 635 x 1326 | 1051x705x1646 | ||
Net weight (kg) | 573 | 650 | 735 | 790 | |
IP protection | IP31 (default), IP42 (optional) | ||||
MANAGE | |||||
Optional SNMP | Power management from SNMP manager and web browser | ||||
dry contact | 5 outputs and 4 inputs | ||||
Modbus RS-232/RS485 | Supports Windows® family, Linux and MAC | ||||
STANDARD | |||||
Safety | IEC62040-1-2017 |