产品概述:Patented Cabinet Structure 100% Front Design Maintenance Giant iND is a fake three-phase online UPS with advanced graphite coating and technical components, wit···
100% positive design and maintenance of patented cabinet structure
Giant iND is a fake three-phase online UPS with advanced graphite coating and technical components, with IP31 IP rated water protection and excellent performance for industrial and harsh environments. In addition, the Giant ND II with its patented machine structure design provides 100% front access for easy maintenance and entry, wiring and removal of components.
main feature
●Patented cabinet structure 100% front design and maintenance
●Apply advanced graphene coating and industrial-grade components for effective heat dissipation
●IP31 protection grade (IP42), can be used in harsh environments
●Key components of international brands with component life cycle management to extend product life cycle
●Design, guarantee product
●Up to 4 units can be operated
●Temperature prolongs battery life
●Feedback protection and built-in 40kA surge protection ensure safe operation
●7-inch LCD display, user-defined control settings and accessible UPS information data
Product Specifications
MODEL | Giant iND II 33-10K | Giant iND II 33-20K | Giant iND II 33-30K | Giant iND II 33-40K | Giant iND II 33-60K | Giant iND II 33-80K | |
CAPACITY | 10KVA/9KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW | 60KVA/54KW | 80KVA/72KW | |
ENTER | |||||||
Rated voltage | 380VAC/400VAC/415VAC | ||||||
acceptable voltage range | 304VAC ~ 456VAC | ||||||
frequency | 50Hz/60Hz ± 10% | ||||||
Rectifier type | 6 pulse | ||||||
Main input and bypass input | Supports dual inputs | ||||||
TVSS | 40kA | ||||||
OUTPUT | |||||||
frequency | 50Hz/60Hz ± 1% | ||||||
power factor | 0.9, customized up to 1.0 | ||||||
overload capacity | 110% continuous running; 125% for 10 min; >150% for 1 min | ||||||
Rated output voltage | 380VAC/400VAC/415VAC | ||||||
Output voltage regulation | ±1% | ||||||
BYPASS | |||||||
Input voltage range | 285VAC ~ 475VAC | ||||||
Rated voltage | 380VAC/400VAC/415VAC | ||||||
BATTERY | |||||||
battery voltage | 384 VDC (Adjustable) | ||||||
Cold start | Yes | ||||||
SURROUNDINGS | |||||||
Operating temperature | 0~ 40°C | ||||||
altitude | 1000m | ||||||
Storage temperature | -25°C ~ 55°C | ||||||
humidity | 0~95% (non-condensing) | ||||||
PHYSICS | |||||||
Dimensions, D X W X H (mm) | 800 x 800 x 1800 | 800 x 1200 x 1800 | |||||
Net weight (kg) | 349 | 385 | 427 | 508 | 563 | 760 | |
IP protection | IP31 (default), IP42 (optional) | ||||||
MANAGE | |||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
dry contact | 5 outputs and 4 inputs | ||||||
Modbus RS-232/RS485 | Supports Windows® family, Linux and MAC | ||||||
STANDARD | |||||||
Safety | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | ||||||
EMC immunity | IEC61000-4-5 | ||||||
Safety | IEC62040-1-2017 | ||||||
EMC emissions | IEC62040-2-2018 |
Model | Giant iND II 33-100K | Giant iND II 33-120K | Giant iND II 33-160K | |
CAPACITY | 100KVA/90KW | 120KVA/108KW | 160KVA/144KW | |
ENTER | ||||
Rated voltage | 380VAC/400VAC/415VAC | |||
acceptable voltage range | 304VAC ~ 456VAC | |||
frequency | 50Hz/60Hz ± 10% | |||
Rectifier type | 12 pulse | |||
Main input and bypass input | Supports dual inputs | |||
TVSS | 40kA | |||
OUTPUT | ||||
frequency | 50Hz/60Hz ± 1% | |||
power factor | 0.9, customized up to 1.0 | |||
overload capacity | 110% continuous running; 125% for 10 min; >150% for 1 min | |||
Rated output voltage | 380VAC/400VAC/415VAC | |||
Output voltage regulation | ±1% | |||
BYPASS | ||||
Input voltage range | 285VAC ~ 475VAC | |||
Rated voltage | 380VAC/400VAC/415VAC | |||
BATTERY | ||||
battery voltage | 384 VDC (Adjustable) | |||
Cold start | Yes | |||
SURROUNDINGS | ||||
Operating temperature | 0~ 40°C | |||
altitude | 1000m | |||
Storage temperature | -25°C ~ 55°C | |||
humidity | 0~95% (non-condensing) | |||
PHYSICS | ||||
Dimensions, D X W X H (mm) | 800 x 1200 x 1800 | 800 x 1600 x 1800 | ||
Net weight (kg) | 850 | 1120 | 1390 | |
IP protection | IP31 (default), IP42 (optional) | |||
MANAGE | ||||
Optional SNMP | Power management from SNMP manager and web browser | |||
dry contact | 5 outputs and 4 inputs | |||
Modbus RS-232/RS485 | Supports Windows® family, Linux and MAC | |||
STANDARD | ||||
Safety | CE / CB/ Conformance testing / EMC / ROHS2 / Reach / YDT1095-2018 | |||
EMC immunity | IEC61000-4-5 | |||
Safety | IEC62040-1-2017 | |||
EMC emissions | IEC62040-2-2018 |