产品概述:The principle of isolation transformer is the same as that of ordinary transformer. All use the principle of electromagnetic induction. Isolation transformers g···
JBK3 series machine tool control transformers are suitable for circuits with AC 50-60Hz and input voltage not exceeding 660V. This series of transformers are other products that control transformers and are manufactured with imported materials and advanced technology. They have reliable operation, low energy consumption, small size, safe wiring, and wide applicability to the point of manufacture. JBK5 series machine tool control transformers are the latest transformer series introduced by our company in Germany in the 1990s. On the basis of domestic JBK3 series machine tool control transformers, after many years of further absorption of similar foreign products, and foreign advanced methods are selected to scale the structure of terminal blocks and connect the terminals Combined with the skeleton, the protection level is increased to IP2LX to prevent accidental contact with the circuit. Using domestic IT cold-pressed terminal blocks, the wiring method can improve the wiring density. The connection between the silicon steel sheet and the silicon steel sheet of the transformer, and the connection between the silicon steel sheet and the bottom plate are all welded by argon arc welding, forming a whole, which is quick and clear. Especially the bottom plate is formed at one time, the installation size is more accurate than the JBK3 series, and the high-quality anti-corrosion alloy material is used, which greatly improves the reliability of the grounding performance and comprehensively improves the product quality. The product conforms to VDE0550, IEC204-1, IEC439, JB/T9446-1999, GB5226 and other relevant international and national standards. Interchangeable with foreign products.
model | JBK3-40~800 series | JBK3-1000~2500 series | JBK-5-40~800 series | JBK-5-100~1600 series | JBK-5-2500 series |
capacity | 40~800VA | 1000~2500VA | 40~800VA | 1000~1600VA | 2500VA |
enter | |||||
Rated voltage | 380V (AC) | ||||
frequency | 50Hz/60Hz ± 10% | ||||
Phase | three phase | ||||
output | |||||
frequency | 50Hz/60Hz ± 1% | ||||
Rated output voltage | 220V (AC) | ||||
Phase | Simplex | ||||
Technical realization | |||||
underlying principle | The principle of isolation transformer is the same as that of ordinary transformer. All use the principle of electromagnetic induction. Isolation transformer generally refers to a 1:1 transformer | ||||
Insulation resistance | 10MΩ | ||||
Power frequency withstand voltage | 2500 V, 1 min, leakage current <10mA | ||||
High frequency interference suppression | Common mode 2500 V (1 MHz ringing wave) rejection >60 dB, differential mode 1250 V (1 MHz ringing wave) rejection >40 dB | ||||
Performance characteristics | Reliable work, low energy consumption, small size, safe wiring, wide applicability | ||||
parameter | |||||
model | JBK3 | JBK5 | |||
Efficiency (η) | 98% | ||||
external structure | vertical | ||||
cooling method | Free cooling | ||||
Moisture-proof way | open | ||||
Number of windings | double winding | ||||
Core structure | cuboid | ||||
Core shape | Type E | ||||
use | |||||
Operating temperature | ≤80°C | ||||
working environment | Keep away from water, fire and other oxidative and fire-prone environments | ||||
Working humidity | 0~90% | ||||
operate | 1. Connect the input terminal of the isolation transformer to the corresponding power supply voltage (380V) 2. Connect the output terminal of the isolation transformer to the power input terminal of the required equipment. 3. Turn on the power and it can be used normally. | ||||
physics | |||||
Dimensions: Front (W) X D (D) X H (mm) | See the table below for details: JBK3 size table | See the table below for details: JBK5 size table | |||
Installation distance | |||||
standard | |||||
international standard | VDE0550, IEC204-1, IEC439 | ||||
domestic standard | JB/T9446-1999, GB5226 | ||||
Be applicable | Can be used interchangeably with foreign products | ||||
Serve | If there is any abnormality during the use of the equipment, please contact the manufacturer in time to deal with it |
JBK3 size chart | ||||||
model | Dimensions | Installation hole distance | Mounting holes | |||
B max | D max | E max | A | C | K×J | |
JBK3-40 | 78 | 70 | 86 | 56±0.5 | 51±3 | 4.8×9 |
JBK3-63 | 78 | 70 | 86 | 56±0.5 | 51±2 | 4.8×9 |
JBK3-100 | 85 | 85 | 93 | 64±0.5 | 67±0.5 | 4.8×9 |
JBK3-160 | 96 | 90 | 103 | 84±0.5 | 74±2 | 5.8×11 |
JBK3-250 | 96 | 105 | 103 | 84±0.5 | 88±2 | 5.8×11 |
JBK3-300 | 96 | 115 | 114 | 84±0.5 | 96±2 | 5.8×11 |
JBK3-400 | 120 | 113 | 123 | 90±0.5 | 90±2 | 7×13 |
JBK3-630 | 150 | 118 | 145 | 122±0.5 | 86±2 | 7×13 |
JBK3-800 | 150 | 128 | 145 | 122±0.5 | 100±2 | 7×13 |
JBK3-1000 | 155 | 205 | 145 | 127.5±2 | 152±2 | 7×12 horizontal |
JBK3-1600 | 180 | 230 | 160 | 140±2 | 176±2 | 7×12 horizontal |
JBK3-2500 | 205 | 260 | 175 | 173±2 | 200±2 | 7×12 horizontal |
JBK5 size chart | ||||||
model | Dimensions | Installation hole distance | Mounting holes | |||
B max | D max | E max | A | C | ||
JBK5-40, 63 | 78 | 72 | 90 | 56 | 46 | 4.6 |
JBK5-100 | 85 | 75 | 96 | 64 | 62 | 4.6 |
JBK5-160 | 96 | 92 | 105 | 84 | 73.5 | 5.5 |
JBK5-250 | 96 | 100 | 104 | 84 | 85 | 5.8 |
JBK5-400 | 120 | 100 | 122 | 90 | 85 | 5.8 |
JBK5-630 | 150 | 110 | 140 | 122 | 90 | 7 |
JBK5-800 | 150 | 128 | 142 | 122 | 105 | 7 |
JBK5-1000 | 150 | 190 | 142 | 126 | 155 | 7 |
JBK5-1000 | 168 | 125 | 155 | 105 | 138 | 9 |
JBK5-1600 | 170 | 225 | 155 | 140 | 176 | 7 |
JBK5-1600 | 168 | 138 | 155 | 116 | 138 | 9 |
JBK5-2500 | 194 | 160 | 165 | 172 | 195 | 7 |